Augmented Reality Navigation Versus Patient-Specific Cutting Guides for Simulated Fronto-Orbital Surface Trajectories in Facial Feminization Surgery: A Preclinical Accuracy Study
Oct 2026· Bioengineering· 0 citations· 22 references
Abstract
This preclinical investigation examined whether optical see-through augmented reality (AR) can transfer planned fronto-orbital cutting paths during simulated frontal debossing compared with patient-specific CAD/CAM cutting guides (CGs). Twenty printed skull replicas derived from one CT dataset were divided equally between workflows. Four superficial frontal or supraorbital grooves were created per skull and evaluated using postoperative CBCT and bidirectional closest-point distances. Overall deviation averaged the four trajectory means within each skull, giving 10 independent observations per group. Skull-level median [Q1, Q3] deviation was 0.543 [0.496, 0.588] mm with CGs and 1.098 [0.907, 1.333] mm with AR. Exact two-sided Mann–Whitney comparisons with Holm correction across overall accuracy, execution time, and four regions favored CGs for overall accuracy (adjusted p = 0.0208), superior frontal and right supraorbital accuracy, and execution time (adjusted p = 0.0029). The median [Q1, Q3] cumulative groove-execution time was 65.5 [61.5, 78.5] s with CGs and 152.0 [131.5, 208.8] s with AR. Mechanical guides deviated less with shorter groove-execution times in this standardized model, while operator and learning effects were not adjusted for. These findings concern surface trajectory reproduction in rigid models; clinical validation and assessment of the complete workflow are needed.
BACKGROUND
Augmented reality (AR) navigation has demonstrated accuracy for pedicle screw placement but has not been well studied for angular trajectories required to access disc spaces and sacroiliac joints (SIJs). This study evaluated the accuracy of AR-guided angular trajectories comparing 2 registration methods: int...
Gabriel Urreola, Jose A. Castillo, Venina S. Kalistratova et al.· The International Journal of...· 0 citations
This study supports the technical feasibility of a patient-specific AR workflow for craniotomy guidance across anatomically different cranial approaches by enabling the translation of patient-specific preoperative planning directly to the operative field and providing AR guidance during the initial stages of cranial su...
N. Montemurro, M. Carbone, R. Viglialoro et al.· Brain Science· 0 citations
AR HMD technology is a promising adjunct for cranial neurosurgical navigation, providing clinically useful accuracy comparable to conventional neuronavigation in selected applications while improving spatial orientation, ergonomics, and surgical workflow.
Ahmad Budirahaji, R. I. Susilo, Joni Wahyuhadi et al.· The Egyptian Journal of Neur...· 0 citations
Hard-tissue surgery requires precise spatial control, while conventional computer-assisted navigation presents guidance separately from the operative field. Augmented reality can bring navigation information closer to the surgeon, but how best to translate this information into intuitive intraoperative guidance remains...
D. Zhao, Y. Qiu, Y. Guo et al.· medRxiv· 0 citations
Extended reality (XR) has increasingly been investigated for visualization and preoperative planning in neurosurgery. However, evaluation has often focused on visualization, usability, technical performance, and task outcomes, while comparatively less attention has been given to quantifying observable planning-rela...
Anna Drechslerová, G. Widhalm, Gilbert Hangel et al.· Frontiers in Digital Health· 0 citations