Energy management optimization algorithm for data center microgrids based on solid-state transformers

Oct 2026 · Scientific Reports · Vol 16 · 0 citations · 69 references

Abstract

The proliferation of hyperscale data centers, together with tightening carbon-neutrality targets, exposes the limits of the line-frequency transformer (LFT) that still dominates data-center power distribution and motivates a fresh look at the conversion and dispatch layer. This paper develops an energy management framework for a data-center microgrid whose grid interface is a three-stage solid-state transformer (SST), so that renewable, storage, and IT loads sit on independently regulated AC and DC ports rather than behind a passive iron core. A multi-objective mixed-integer nonlinear program (MOMINLP) is formulated to jointly minimise operating cost, carbon emission, a composite power-quality index, and average PUE, subject to bus power balance, SST port transfer, battery SOC, ramp, and demand-response constraints. Uncertainty in PV, wind, and IT workload is condensed through Latin hypercube sampling with Kantorovich-based scenario reduction, and tail risk is capped by a CVaR constraint at the 95% confidence level. Dispatch is decomposed across day-ahead, intra-day, and real-time MPC layers, and the nonconvex problem is solved by an improved whale optimization algorithm (IWOA) that combines Tent chaotic initialization, an adaptive convergence coefficient, differential-evolution mutation, and Lagrangian relaxation of the diesel and battery integer commitments. On a 10 MW-class pilot the proposed scheme raises renewable accommodation by 17.2% points, cuts annual operating cost by 11.7%, reduces \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\:{CO}_{2}$$\end{document} emissions by 12.9%, and lowers average PUE from 1.52 to 1.40 relative to a line-frequency-transformer baseline, while keeping bus voltage deviation below 1.7% on the DC bus and 2.4% on the AC bus. Against PSO, GA, standard WOA, and NSGA-II, IWOA halves the iterations needed to reach 1% of the final fitness (78 versus 134–187), tightens the relative gap to the best-known solution to 0.62% (versus 2.4–5.1%), and drops the coefficient of variation to 0.018 (versus 0.061–0.094), showing that the observed gains come from the coupling of hardware-aware modelling and algorithmic tailoring rather than from either alone.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.