Bond strength evaluation between 3D-printed provisional resins and relining materials after different surface treatments
Abstract
3D printing has been increasingly incorporated into prosthetic dentistry for the efficient fabrication of provisional restorations. Clinical scenarios frequently require chairside relining to correct marginal discrepancies or accommodate soft tissue changes. However, evidence on adhesion between 3D-printed substrates and relining materials remains scarce, and standardized protocols are lacking. This in vitro study evaluated shear bond strength between two 3D-printed provisional resins (Prizma BioCrown and dima Print C&B Temp) and relining materials after four surface treatments. Testing was performed in a universal testing machine, with failure modes analyzed by stereomicroscopy (ANOVA and Tukey's test, α = 0.05). Both surface treatment and resin type significantly affected bond strength (p < 0.05). Predominantly adhesive failures in low-strength groups shifted toward cohesive and mixed failures in high-strength groups. Airborne-particle abrasion combined with universal adhesive and self-cure resin relining was the most effective protocol tested.