Oct 2026· Italian National Conference on Sensors· 0 citations· 34 references
TL;DR
The results support PCPD as a promising PPG-only peak detector and motivate further validation under real motion artifacts and for downstream signal quality assessment.
Abstract
Photoplethysmography (PPG) is a widely used, non-invasive technique for heart rate monitoring, but its reliability is often compromised by noise and motion artifacts (MAs). This study presents the Peakwise Correlation Pulse Detector (PCPD), an algorithm for detecting heartbeats directly from PPG signals without requiring electrocardiogram (ECG) signals during operation, evaluated here under clean and controlled synthetic pulse-free-noise conditions. PCPD follows a five-step pipeline: (1) signal segmentation with overlap, (2) sliding cross-correlation using high-quality heartbeat templates, (3) computation of the Minimum Correlation Curve (MCC), (4) feature extraction with machine learning-based classification, and (5) peak translation with constraint analysis. The method was evaluated on a clean dataset, comprising a newly collected PPG dataset with manually annotated signal quality and the publicly available BIDMC dataset, and on a noisy dataset that augments the clean data with synthetic pulse-free segments generated from band-limited Gaussian noise. This evaluation framework tests heartbeat detectors under ideal conditions and under a controlled non-informative-noise protocol. On clean signals, PCPD achieved balanced precision–recall scores of 99.13% on the proposed dataset (internal performance) and 97.04% on the independent BIDMC dataset. Under added synthetic pulse-free noise, PCPD achieved accuracies of 99.30% and 97.16% on the proposed and BIDMC datasets, respectively. In comparative experiments against eleven benchmark heartbeat detection algorithms, PCPD achieved the best performance among the evaluated implementations under the tested synthetic-noise protocol. These results support PCPD as a promising PPG-only peak detector and motivate further validation under real motion artifacts and for downstream signal quality assessment.
Photoplethysmography (PPG) is widely used in wearable devices, but wrist- and arm-worn recordings are sensitive to motion artifacts, ambient light, and changes in sensor–skin contact. This study presents an adaptive preprocessing pipeline that combines accelerometer-derived motion-state clustering, an ambient-light-bas...
Matteo Ricci, D. Suárez, Vicente Bertomeu-González et al.· Italian National Conference...· 0 citations
Continuous and unobtrusive blood pressure monitoring is vital for the early diagnosis and effective management of cardiovascular diseases. Conventional pneumatic cuffs cause physical discomfort during repeated measurements, while invasive catheterization poses substantial clinical risks. To overcome these limitations,...
Bing-Zhen Zhao· Science and Technology of En...· 0 citations
Introduction Cardiac arrhythmias often progress without clear symptoms and may remain undetected until severe complications occur. Continuous monitoring through consumer smartwatches offers a scalable and non-invasive opportunity for real-time rhythm screening in free-living conditions. However, wrist-based photoplethy...
Dan-Cristian George, Mihai-Alexandru Hulubeac, Ştefan-Lucian Grămadă et al.· Frontiers in Artificial Inte...· 0 citations
Diabetes mellitus is a major global health challenge, and routine blood glucose monitoring still depends on invasive fingerstick sampling. This study examines non-invasive glucose estimation from photoplethysmography (PPG) using a signal quality pipeline and a multi-criteria feature selection framework. PPG recordings...