Oct 2026· Clinical and Translational Radiation Oncology· Vol 62, pp. 101321· 0 citations· 26 references
Medicine
TL;DR
The feasibility of a 5 mm isotropic PTV in whole bladder MRIgART with 5 mm isotropic PTV margins with a personalised approach to margin expansion is feasible in achieving acceptable CTV coverage.
Abstract
Introduction Bladder MRI-guided online adaptive radiotherapy (MRIgART) has enabled a reduction in planning target volume (PTV) margins, reducing normal tissue irradiation. Yet, further margin reduction is limited due to workflow duration and intra-fractional bladder variation. This study reports the feasibility of a 5 mm isotropic PTV in whole bladder MRIgART, 55 Gy in 20 fractions daily, and 36 Gy in 6 fractions weekly, with a personalised approach to margin expansion. Methods Patients voided their bladders prior to treatment. Following setup, a daily MRI (MRDAILY) was acquired, and an adaptive workflow was performed. An MRI was acquired during delivery to coincide with treatment completion (MRPOST). Time from MRDAILY to MRPOST was recorded. Offline, target coverage of the clinical target volume (CTV) was visually monitored by comparing MRDAILY and MRPOST images. Images were reviewed by the radiation oncologist (RO) if the CTV was outside of the PTV on the MRPOST. Under RO discretion, margins were personalised to the minimum margin that would have encompassed the CTV and applied online for subsequent fractions. In retrospective analysis, MRPOST CTVs were recontoured, and the adaptive plan recalculated. CTV coverage was deemed acceptable if V95% ≥ 95%. If this objective was not met, the gross tumour volume (GTV) was delineated and the dose reported; coverage was deemed acceptable if GTV V95% ≥ 95%. Results A total of 138 fractions from ten patients were analysed. Median (interquartile range) workflow time was 25.6 (20.8–30.7) minutes. PTV margins were personalised for 31 fractions in three patients. 119 MRPOST images were available for analysis. CTV coverage was achieved in 94% (112/119) of fractions. Where the CTV mandatory objectives were missed (6%; 7/119 fractions), GTV coverage was acceptable in 6 of the 7 fractions. Conclusion Whole bladder MRIgART with 5 mm isotropic PTV margins with a personalised approach to margin expansion is feasible in achieving acceptable CTV coverage.
INTRODUCTION
Interfractional anatomical variations during pelvic radiotherapy for locally advanced cervical cancer may compromise target coverage and increase organ-at-risk (OAR) irradiation. This study evaluated the feasibility and dosimetric impact of a cone-beam CT (CBCT)-guided Plan-of-the-Day (PoD) adaptive radiot...
M. Ben Rejeb, S. Lahiouel, A. Hamdoun et al.· Radiography· 0 citations
Daily CBCT image-guided couch corrections maintain dosimetric accuracy during hypofractionated prostate radiotherapy and support safe implementation of tight PTV margins in resource-constrained public-sector healthcare settings.
Leanore Legoale-Sebopa, Sheynaz Bassa, H. V. Maselesele· South African Journal of Onc...· 0 citations
Introduction Online adaptive radiotherapy (oART) may improve head and neck cancer (HNC) treatment, where anatomical changes during radiotherapy (RT) are common. However, oART is resource-intensive and clinical data are limited. We conducted a prospective feasibility trial implementating an RT technologist (RTT)-led wor...
A. Lindegaard, K. Håkansson, A. Appelt et al.· Clinical and Translational R...· 0 citations
Residual intrafraction motion produced directionally asymmetric coverage loss, with the largest effect on the boosted GTV, and motion-inclusive dose reconstruction enabled derivation of practical asymmetric margins that improved robustness while identifying the tradeoff between target coverage and delivery efficiency.
Ka-Ho Tam, S. Jogi, A. Sobremonte et al.· medRxiv· 0 citations
PURPOSE
Magnetic resonance image-guided adaptive brachytherapy (MR-IGABT) is the standard of care for definitive radiochemotherapy in locally advanced cervical cancer, but radiotherapy departments with sufficient case volume and unrestricted access to MRI capacity remain limited. This study evaluated the feasibility an...
J. Knoth, H. Ramadan, E. Weis et al.· Strahlentherapie und Onkolog...· 0 citations
INTRODUCTION
In recent years, cervical cancer incidence has been on the decline in Australia, likely due to the HPV vaccination and an improved screening programme. However, an estimated 900 new cases will be diagnosed in 2025. The standard of care for locally advanced cervical cancer (LACC) is chemoradiotherapy, compr...
L. Edwards, H. Tan, K. Rahim et al.· Journal of Medical Imaging a...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.