Frequency-spatial and gradient-guided conditional diffusion for high-b-value dMRI synthesis
Abstract
High-b-value diffusion-weighted MRI (dMRI) can improve sensitivity to restricted diffusion. Direct acquisition, however, is limited by scan time, signal-to-noise ratio and motion artefacts. We present a compact conditional diffusion framework for synthesizing b=1000 s/mm² dMRI from b=0 images. The model extends SynDiff with frequency-spatial dual-branch convolution and gradient-guided attention. Training and validation used the IXI dataset, including 17,470 training slices and 1,891 validation slices. Independent testing used a private clinical dataset of 20 participants and 1,124 slices. On IXI validation data, PSNR increased from 28.093dB to 28.423dB, and SSIM increased from 0.8869 to 0.8889. On the private clinical test set, PSNR increased from 23.015dB to 23.533dB, and SSIM increased from 0.8403 to 0.8494. Ablation analysis supported the contribution of both modules. Corrected testing supported the main PSNR comparisons, whereas private-dataset SSIM showed a non-significant trend. Representative images and error maps suggested improved local structural preservation. These findings support frequency-spatial and gradient-guided modelling for high-b-value dMRI synthesis. Further validation remains necessary before clinical use.