Skip to content
Conference Open access

Multipurpose particle detector for fixed-target experiments based on plastic scintillators and SiPMs (time resolution)

2026 · EPJ Web of Conferences · 0 citations · 1 references

Abstract

Fixed-target experiments in nuclear and particle physics require robust, modular, and high-efficiency detection systems capable of accurately recording particle passage, time of arrival, and the information needed for trigger tasks. This work presents the initial design of a multipurpose particle detector for fixed-target configurations based on plastic scintillators coupled to silicon photomultipliers (SiPMs). The overall concept considers modules built from rectangular scintillator bars with optical readout at both ends using SiPMs in order to maximize light collection and reduce optical losses associated with coupling. The design also addresses relevant experimental aspects such as SiPM thermal stability, treated here at the design level and not characterized in the present prototype, dark-count mitigation, and compatibility with high-speed front-end electronics. The system is complemented by a multichannel signal-conditioning and digitization chain that enables the extraction of amplitude and timing information through discrimination techniques and time analysis. At the current stage of development, only preliminary studies focused on the time resolution of a validation prototype are reported. The initial results show a reproducible response and an adequate operating margin for establishing stable trigger thresholds. Taken together, this approach confirms that the combination of plastic scintillators and SiPMs is a compact, scalable, and low-power alternative for applications in environments with magnetic fields and geometric constraints.

Read PDF

Similar papers

Preprint Nov 2026

Construction and performance evaluation of a meter-scale monolithic scintillator tracker with embedded scatterers

A meter-scale Fiber-Readout mOnolithic and Scatterer-embedded scintillator Tracker (FROST) was constructed and operated in the NINJA experiment to enable muon-track matching between the nuclear emulsion detectors and the downstream muon detector. The detector consists of a 1.32 m $\times$ 1.40 m plastic scintillator pl...

N. Otani, S. Han, E. Abad Díaz et al. · 0 citations
Preprint Sep 2026

Commissioning and Performance of the Time-of-Flight Detector for the T2K Neutrino Oscillation Experiment

The T2K ND280 Upgrade aims to reduce systematic uncertainties in measurements of neutrino oscillation parameters and improve sensitivity to the charge-parity (CP)-violating phase, $\delta_{\mathrm{CP}}$. A key component is the Time-of-Flight (ToF) detector, comprising six panels with 118 EJ-200 plastic-scintillator bar...

C. Alt, L. Amziane, N. Baudis et al. · 0 citations
Open access Oct 2026

The RUBIK satellite payload concept: a 3D-segmented plastic scintillation-based particle tracking detector

We present the design concept and first experimental results of RUBIK, a three-dimensional resolving plastic scintillation detector developed as a scientific payload for the Research and Observation in Medium Earth Orbit satellite mission of the Institute of Space Systems of the University of Stuttgart. The name RUBIK...

R. Bergert, D. Kazlou, Hartmut Schotte et al. · 0 citations
Preprint Sep 2026

Design and characterization of large-size monolithic layers of 3D-segmented plastic scintillator

Three-dimensional fine-grained plastic scintillator detectors are extensively used in high-energy physics experiments where particle tracking, identification, calorimetry and sub-nanosecond timing information are required. Moreover, the low cost of plastic scintillator makes, in principle, the scalability to multi-tonn...

Jon Berisha, Xing-Yu Zhao, A. Boyarintsev et al. · 0 citations
Preprint Oct 2026

Radiation damage and recovery of SiPMs exposed to low-momentum muon beams for innovative scintillation-based muon beam monitors

Silicon PhotoMultipliers (SiPMs) are among the standard devices for light detection in scintillator detectors. Some detector designs require these devices to be placed in radioactive areas or directly exposed to particle beams. Specifically, the damage from exposure to low-momentum muons is particularly important, as t...

Riccardo Rossini, Sayani Biswas, Adrian D. Hillier et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.