Abstract

An increased number of premature atrial contractions (PACs) has been associated with an increased risk of atrial fibrillation (AF) and ischemic stroke. Prior studies used 24-hours or 48-hours of ECG monitoring and thresholds of ≥720 PACs/24 hours to define excessive supraventricular ectopy (ESVEA). To determine whether shorter durations of ECG monitoring (e.g. one hour) would suffice to identify most patients who have ≥720 PACs/24 hours. FIND-AF 2 is a multicenter trial including patients ≥60 years with recent ischemic stroke and no prior AF. Patients are randomized to enhanced, prolonged and intensified ECG monitoring or usual care. All patients received a 24-hours Holter-ECG prior to randomization to exclude AF and to quantify the number of PACs. In this analysis, 5,231 patients with complete 24-hours Holter-ECGs and without AF were evaluated. Holter-ECGs were divided into hourly intervals. PAC positivity was defined as ≥30 PACs in at least one hour. The ≥720 PAC/24 hours criterion served as reference standard. Sensitivity, specificity, and the Youden index were calculated across cumulative monitoring durations. Distributional analyses were performed among PAC-positive recordings. A total of 1,054 recordings met the ≥720 PAC/24 hours criterion. Overall, 2,147 Holter-ECGs were classified as PAC-positive. Among PAC-positive recordings, patients with ≥720 PAC/24 hours exhibited a substantially higher number of hours with ≥30 PACs compared with <720 PAC/24 hours (median 17 vs 2 hours, p<0.001), demonstrating near-complete separation of distributions (Figure 1). After 1 hour, the ≥30 PAC threshold showed high specificity (96%) and moderate sensitivity (70%) for identifying ≥720 PAC/24 hours. Sensitivity increased while specificity declined with longer monitoring, with optimal discrimination after 7 hours (Youden index 0.801; sensitivity 94%, specificity 86%) (Figure 2). High daily PAC burden reflects sustained hourly PAC activity rather than isolated peaks. A single-hour threshold provides a highly specific early rule-in approach, while 7-hour monitoring achieves optimal balance. Short ECG monitoring for a few hours may be used to risk-stratify ischemic stroke patients for prolonged ECG monitoring.Figure 1Figure 2.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.