Skip to content
Open access

Automated Detection of Positioning Errors in Bitewing Radiographs Using Deep Learning

Nov 2026 · Clinical and Experimental Dental Research · Vol 12 · 0 citations · 36 references
Medicine

TL;DR

The CNN‐based system showed strong performance for bitewing type, side, binary cone‐cutting error, and interproximal overlap classification in mannequin‐acquired radiographs, and support the potential use of deep learning for radiographic quality assessment in education and quality‐control workflows.

Abstract

ABSTRACT Objectives Bitewing radiographs (BWs) are essential diagnostic tools in dentistry, but are often affected by positioning errors, compromising their diagnostic value and increasing retake rates. This study aimed to develop and evaluate a deep learning‐based automated system for detecting and classifying BW type (premolar/molar), side (right/left), and common positioning errors in a controlled mannequin‐based setting. Methods A total of 403 BWs were collected from dental student assessments acquired from dental radiology mannequins. BWs were consensus‐labeled by dentomaxillofacial radiology experts for type, side, and the most common positioning errors. A balanced data set supported training and validation. Convolutional neural network architectures, including ResNet and DenseNet variants, were trained from scratch and evaluated as independent classification tasks using stratified fivefold cross‐validation. Performance was assessed using accuracy, precision, recall, F1 score, and area under the curve, reported as mean ± standard deviation across folds. A confusion matrix was generated for multi‐class cone‐cutting error (CCE) severity classification. Results The system achieved accuracies of 95.8% for BW type classification, 99.0% for side classification, 96.3% for CCE detection, and 93.4% for interproximal overlap detection. Multi‐class CCE classification achieved an accuracy of 79.3%, with reliable identification of “critical” and “minimal” errors. Detection of incorrect receptor placement achieved an accuracy of 73.2%. Conclusions The CNN‐based system showed strong performance for bitewing type, side, binary cone‐cutting error, and interproximal overlap classification in mannequin‐acquired radiographs. Performance was more limited for multi‐class cone‐cutting severity and incorrect receptor placement. These findings support the potential use of deep learning for radiographic quality assessment in education and quality‐control workflows. A validation study using patient‐acquired bitewing radiographs from clinical settings is required before clinical deployment.

Read PDF

Similar papers

Open access Oct 2026

Automated Detection and Segmentation of Dental Caries in Panoramic Radiographs Using YOLOv8-Based Deep Learning Model

Abstract Objectives This study aimed to develop an automated dental caries localization system through detection and classification using a deep learning (DL) approach based on You Only Look Once Version 8 (YOLOv8). Materials and Methods YOLOv8 models were developed using 750 panoramic radiographs, which were divided i...

R. Putra, E. Astuti, Aga Satria Nurrachman et al. · 0 citations
Sep 2026

Diagnostic Accuracy of Deep Learning for Detection of Incipient and Advanced Radiographic Interproximal Caries in Mixed Dentition Periapical Radiographs.

The observed differences among detection architectures and inference configurations provide a foundation for developing more accurate AI-assisted detection systems, although clinical examination remains essential for determining lesion activity, cavitation status, and treatment decisions.

M. Baraka, Abdallah Elsayed, Ahmed Issa et al. · 1 citation
Open access Nov 2026

Transfer Learning-Based Classification of Dental Implant Types from Panoramic Radiographic Images

Accurate recognition of dental implant type from panoramic radiographs is relevant for prosthetic planning, follow-up assessment, implant maintenance, and retrospective clinical documentation. Manual identification may be difficult when implant borders are partially visible, when metal artifacts obscure relevant struct...

Shahid Mohammad Ganie · 0 citations
Open access Sep 2026

Automated Root Canal Curvature Assessment From Periapical Radiographs Using Geometric and Deep Learning Features.

This framework works best as a screening aid as it helps identify canals that need adjunctive three-dimensional evaluation and has higher sensitivity for severe curvature, compared to the limitations of two-dimensional radiographs in displaying buccolingual curvatures.

Balaganesh Pachaiappan, S. Poorni, Srividhya Srinivasan et al. · 0 citations
Oct 2026

Deep Learning-Based Detection of Radiolucent Jaw Lesions on Panoramic Radiographs: A Comparative Study.

This retrospective study aimed to compare the performance of different deep learning-based object detection models for detecting radiolucent jaw lesions on panoramic radiographs. A total of 600 panoramic radiographs showing radiolucent jaw lesions were included in the study. All images were anonymized and manually anno...

Emre Yapıcıoğlu, K. Ağaçayak · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.