Aug 2026· Italian National Conference on Sensors· Vol 26, pp. 4982· 0 citations· 60 references
Medicine
TL;DR
NSE YOLO enables automated quantification of anterior chamber depth and bilateral iridocorneal angles for post-ICL follow-up assessment, providing preliminary technical validation supporting further external and device-level evaluation.
Abstract
Anterior segment optical coherence tomography (AS-OCT) is essential for structural assessment of the anterior eye, yet automated landmark localization remains challenged by pervasive speckle noise, indistinct tissue interfaces, and labor-intensive manual annotation with notable inter-observer variability. This study presents NSE YOLO, an enhanced YOLOv11 framework for high-precision landmark localization in AS-OCT images after implantable collamer lens (ICL) implantation. It integrates a dual-branch NewConv module for multi-scale feature extraction, a dual-additive residual self-attention block (SABlock) to suppress background interference, and a Mamba-based EfficientViMBlock embedded in the C3k2 module to balance global contextual modeling and computational efficiency. Validated on 672 expert-annotated postoperative ICL images from 60 patients, NSE YOLO achieved an mAP@0.5 of 90.7% and mAP@0.5:0.95 of 85.1%, outperforming the YOLOv11 baseline by 5.2% and 6.6% with only 2.86 million parameters. Bland–Altman analysis showed negligible systematic bias and narrow limits of agreement for anterior chamber depth. For iridocorneal angle measurements, directional deviations and wider limits of agreement were observed, with performance approaching the level of inter-observer variability among human annotators. NSE YOLO enables automated quantification of anterior chamber depth and bilateral iridocorneal angles for post-ICL follow-up assessment, providing preliminary technical validation supporting further external and device-level evaluation.
Variability in ultra-widefield (UWF) fundus image acquisition and the lack of standardized post-acquisition processing complicate longitudinal monitoring and quantitative analysis because of differences in retinal coverage, image orientation, and acquisition-related artifacts. This study developed a deep learning-based...
Richul Oh, Jeong Min Lee, Won Jung Lee et al.· Journal of imaging informati...· 0 citations
A systematic comparative evaluation of three deep learning-based segmentation architectures — U-Net, U-Net++, and Y-Net — for automated identification of DME and Intraretinal Fluid regions in OCT scans demonstrates the feasibility of deep learning-based OCT segmentation as a diagnostic support tool in resource-constrai...
Dhiraj Pyakurel, Yokisha Poudel, Sushiksha Prasai et al.· Journal of Hillside College...· 0 citations
Manual segmentation and evaluation of optical coherence tomography (OCT) images are difficult and rely on specialist training, which limits the output in a busy clinic. While automatic segmentation can ease this burden, the deep models that currently lead the field tend to be too heavy for routine deployment on sta...
Mehmood Nawaz, Syed Muhammad Tariq Abbasi, Sheheryar Khan et al.· Frontiers in Digital Health· 0 citations
Thickness estimates derived from the predicted boundaries showed low error across corneal regions, supporting the proposed ARCOS method's use for quantitative corneal OCT analysis.
Nuno Vivas Brás, B. Memmi, Maëlle Bouhassane et al.· 0 citations
Abstract Aims Intravascular optical coherence tomography (OCT) enables high-resolution imaging of the coronary vessel wall, but manual image interpretation is time-consuming and existing automated approaches often require high computational resources and exhibit slow inference times, limiting clinical use. We developed...
Ruben G. A. van der Waerden, R. Volleberg, Pierandrea Cancian et al.· European Heart Journal - Dig...· 0 citations