Direct Predictive Controller Optimization Using Grey Wolf Optimizer for Shunt Active Power Filters
Abstract
This paper presents an optimization-based controller tuning strategy for a Shunt Active Power Filter (SAPF) using the Grey Wolf Optimizer (GWO) to improve the DC-link voltage regulation and harmonic compensation performance. The proposed approach is validated under two scenarios: (i) a standalone nonlinear load system and (ii) a six-bus distribution system. In the first scenario, the optimized controller reduces the DC-link overshoot from 14.42% to 1.82% (approximately 87% improvement), and reduces the Total Harmonic Distortion (THD) by 49.6%. When the optimized controller is integrated into the six-bus system, it maintains robust performance under both balanced and unbalanced grid conditions. Under balanced operation, the proposed controller achieves a 96.1% reduction in overshoot and a 58.25% reduction in THD. Under a 3% voltage unbalance factor (VUF), the optimized controller reduces the overshoot by 98.7% and the THD by 70.5% compared with the conventional PI controller.