Skip to content
Open access

Physics‐informed depth‐enhanced surface tracking for cumulative dose reconstruction in breast radiotherapy: An in silico feasibility study

Oct 2026 · Journal of Applied Clinical Medical Physics · Vol 27 · 0 citations · 36 references
Medicine

TL;DR

The integration of geometric surface features with patient‐specific physical constraints successfully prevents nonphysiological deformation artifacts caused by sensor noise and demonstrates the feasibility and computational efficiency of the PIDE framework for rapid cumulative dose monitoring.

Abstract

Abstract Purpose Surface guided radiotherapy (SGRT) provides nonionizing motion monitoring but lacks direct correlation with internal dosimetric changes. Purely data‐driven models for surface‐to‐internal deformation prediction often yield biomechanically implausible results. This study proposes a physics‐informed depth‐enhanced (PIDE) framework, validated in silico, to reconstruct internal deformation and cumulative dose from noisy surface measurements. Methods A virtual clinical trial (VCT) was conducted using weekly cone‐beam CT (CBCT) data from 29 breast cancer patients. We simulated consumer‐grade RGB‐D sensor noise (σ∝z2) on extracted patient surfaces. To map external surface features to internal deformation vector fields (DVF), we developed a regularized ridge regression model. Unlike traditional models, ours integrates a spectral energy penalty derived from patient‐specific CBCT motion priors, constraining predictions to physically plausible deformations. Patient‐specific clinical RTDOSE distributions and 348 anatomical landmarks were utilized to evaluate the dosimetric and geometric accuracy. Vector field smoothness was quantified using the Jacobian determinant. Results Under realistic simulated sensor noise, the PIDE framework achieved an anatomical target registration error (TRE) of 1.33 ± 1.42 mm (compared to an initial misalignment of 2.14 ± 2.38 mm, representing a 37.8% error reduction). The physics‐constrained regression yielded an RMSE of 2.31 mm (r = 0.720) for motion prediction and effectively eliminated nonphysical tissue “folding” artifacts (reducing negative Jacobian voxels from 0.54% to 0.10%, p = 0.0209). Dosimetric evaluation using actual patient treatment plans achieved a mean Gamma passing rate (3%/3 mm) of 99.68 ± 0.30% (range: 99.00%–100.00%), with 100% of patients (29/29) exceeding the 90% clinical safety threshold. The end‐to‐end algorithmic inference latency was 2.71 ms per frame, demonstrating high computational efficiency. Conclusion The integration of geometric surface features with patient‐specific physical constraints successfully prevents nonphysiological deformation artifacts caused by sensor noise. This in silico study demonstrates the feasibility and computational efficiency of the PIDE framework for rapid cumulative dose monitoring.

Read PDF

Similar papers

Open access Sep 2026

Commissioning and end‐to‐end validation of a combined surface‐guided and triggered kV imaging workflow for breath‐hold SBRT on a Varian TrueBeam

Abstract Background Respiratory motion introduces significant geometric uncertainty in Stereotactic Body Radiotherapy (SBRT) for thoracic and abdominal tumors. Deep Inspiration Breath‐Hold (DIBH) mitigates this, but the surface signal alone may not reflect internal target position, supporting the need for real‐time int...

Offormata Osunkwor, A. Ndlovu, R. Teboh · 0 citations
Open access Oct 2026

Impact of tissue heterogeneity on intracranial Cesium‐131 brachytherapy dosimetry: A patient‐specific Monte Carlo Study

Abstract Background AAPM TG‐43‐based dose calculations for intracranial cesium‐131 (131Cs) brachytherapy ignore patient‐specific heterogeneities, which can affect dose accuracy. This study investigates the dosimetric impact of these heterogeneity effects using Monte Carlo (MC) simulations and patient‐specific imaging d...

Tirthraj Adhikari, J. Jung, Sherif M. Gadoue et al. · 0 citations
Open access Nov 2026

Development of a phantom‐based end‐to‐end QA workflow for online adaptive radiotherapy incorporating high‐resolution 2D detector measurements

Abstract Background Online adaptive radiotherapy (oART) accounts for anatomical changes by adjusting treatment plans on a daily basis. However, comprehensive plan‐specific quality assurance (QA) is challenging, as pre‐treatment measurements cannot be performed with the patient on the treatment couch. Therefore, an end‐...

J. Niedling, R. Schindhelm, Luis Cervantes et al. · 0 citations
Open access Oct 2026

Quantitative analysis of motion-induced dose uncertainty and robust optimization in liver lattice radiotherapy: a comparative study

Background The precise delivery of high doses to lattice vertices in liver lattice radiotherapy (LRT) can be compromised by respiratory motion.This study aimed to quantitatively characterize the dosimetric impact of respiratory motion on liver LRT and to assess the potential of four-dimensional (4D) robust optimization...

Gu-Yu Dai, Shuo-Kai Jia, Jun-Chen Shi et al. · 0 citations
Open access Oct 2026

Dosimetric Vulnerability of Radiotherapy Techniques Under Non-Rigid Arm-Position-Induced Deformations in Breast Cancer: A Deformable Phantom Study

Accurate positioning is essential in breast radiotherapy; however, rigid phantoms do not reproduce posture-related anatomical deformation. We developed a breast-mimicking rubber and silicone phantom to evaluate dosimetric effects of arm-position-induced deformation in three-dimensional conformal radiotherapy (3D-CRT),...

S. H. Park, Jinhyun Choi · 0 citations
Review Open access Oct 2026

Dynamic control of carbon‐ion radiation dose distribution amid respiratory motion challenges: A review of prediction research using geant4 and deep learning physics‐constrained models

Combining Geant4‐based Monte Carlo simulations with deep learning frameworks shows emerging promise for controlling carbon ion dose distributions amid respiratory motion, though direct clinical validation for this combination remains limited.

Jian-Hua Ding, Peng Li, C. H. Yeong · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.