Oct 2026· ACS Omega· Vol 11, pp. 67308 - 67316· 0 citations· 29 references
Medicine
Abstract
Trace element monitoring in fish tissues requires reliable and sustainable sample preparation methods, particularly for complex biological matrices. In this study, an acid-free microwave-assisted digestion (AFMAD) method based exclusively on H2O2 was developed and optimized for multielement determination in fish tissues by ICP–MS. A central composite design coupled with response surface methodology was employed to evaluate the influence of H2O2 concentration, ramp time, and digestion temperature on matrix decomposition efficiency using 100 mg of dry fish tissue subsamples throughout the method development. The optimized conditions consisted of 30% (v/v)H2O2, 8 min ramp time, a 20 min hold time and 240 °C, resulting in residual carbon contents below 20%, which indicates efficient oxidation of the organic matrix using H2O2 in the absence of HNO3. The analytical performance of the proposed method was evaluated using cod muscle certified reference material (BCR-422), providing recoveries ranging from 76 to 101% for Fe, Cu, Zn, Mn, As, and Cd. Excellent linearity was obtained for all analytes (R 2 > 0.990) within the 0–50 μg L–1 range. Limits of detection ranged from 0.0004 to 0.04 μg g–1, demonstrating suitable sensitivity for trace elemental analysis in fish matrices. The applicability of the method was demonstrated through the analysis of five commercial fish species collected in the Mariana-MG region. Concentrations of toxic elements were found in Megaleporinus conirostris (Cd, 0.003 mg kg–1) and Cichla ocellaris (As, 0.07 mg kg–1) and remained below the maximum limits established by Brazilian legislation. The proposed AFMAD method demonstrated satisfactory analytical performance for complex fish matrices while eliminating the use of concentrated mineral acids, reducing hazardous reagent consumption, and improving the sustainability characteristics of sample preparation procedures for elemental analysis.
Reliable isolation of microplastics (MPs) from cured fish products remains challenging because their complex matrices, characterized by high lipid, protein, salt, and mineral contents, hinder organic matter digestion and compromise polymer recovery. In this study, a sequential hydrogen peroxide (H₂O₂)–potassium hydro...
A. Mohamed, K. A. Martin Xavier, Soibam Ngasotter et al.· Microplastics and Nanoplasti...· 0 citations
An ultrasound-assisted dispersive liquid-liquid microextraction method using a magnetic eutectic mixture has been developed for the multi-elemental determination of Al, Ba, Cd, Cr, Cu, Mn, Mo, Ni, Pb, Ti, V, and Zn in edible oils by inductively coupled plasma optical emission spectrometry. A two-step multivariate appro...
Nicolás A. Nario, M. A. Aguirre, M. Grünhut et al.· Food Chemistry· 0 citations
This study aimed to develop and validate a vortex-assisted liquid-phase microextraction (VA-LPME) method based on a magnetic deep eutectic solvent (MDES) for the determination of mercury in seafood samples by cold vapor atomic absorption spectrometry (CV-AAS). The MDES was prepared from menthol and octanoic acid, and F...
de Assis Rosivan dos Santos, L. B. Santos, Márcio Souza Santos et al.· Food Analytical Methods· 0 citations
This study presents a novel, selective, and rapid magnetic solid-phase extraction (MSPE) method coupled with HPLC-DAD for the trace-level determination of apremilast (APM). To achieve high extraction efficiency and minimize matrix interferences, Fe3O4 magnetic nanoparticles were functionalized using a synchronized trim...
Sefa Tütüncü, H. I. Ulusoy· Analytical Methods· 0 citations
Reliable compositional quality control of Ti-doped LiFePO4 (LFP) requires quantitative release of the low-level Ti dopant from a carbon-coated phosphate matrix. We evaluated aqua regia hot-plate digestion and developed a closed-vessel microwave digestion–inductively coupled plasma optical emission spectrometry (ICP-OES...
Myung-Gyu Lee, Tae-Young Kim, Sam-Hang Yi et al.· Molecules· 0 citations