Skip to content
Open access

Predictors of complete occlusion in endovascular coiling of very small intracranial aneurysms.

Oct 2026 · Neuroradiology · 0 citations · 10 references
Medicine

Abstract

Background

Very small intracranial aneurysms (VSAs ≤ 3 mm) are increasingly treated endovascularly, yet procedural fragility and long-term durability remain disputed. Device miniaturization and adjunctive balloon- or stent assistance have improved immediate occlusion, but contemporary single-center outcome data with multivariable modeling are sparse.

Methods

We retrospectively analyzed a prospectively maintained database (2013-2024) for all VSAs treated endovascularly. Demographics, aneurysm morphology, and procedural details were abstracted from digital subtraction angiography (DSA). At the last follow-up, the primary endpoint was complete occlusion; secondary endpoints were favorable functional outcomes, retreatment, and procedural complications. Multivariable logistic regression was adjusted for rupture status, aneurysm width, location, adjunct use, and immediate occlusion.

Results

One-hundred-eighty-five very small intracranial aneurysms (VSAs ≤ 3 mm) (median dome 2.6 mm, 21% < 2 mm) were treated in 185 patients (median age 57.9 years, 71.9% female). 34% presented ruptured; 56% were bifurcation lesions, most commonly at the anterior communicating complex (34.6%). Balloon-assist, stent-assist, and flow diversion were used in 32.4%, 42.7%, and 4.9%, respectively. Immediate complete occlusion was achieved in 53%; at a median 12-month imaging follow-up, complete occlusion was 74.6%, and the retreatment rate was 9.7%. Procedural complications occurred in 10.8% overall, comprising major complications 2.2% (intra-operative rupture 1.1%, thromboembolism 1.1%) and other complications 8.6% ; there were no procedure-related deaths. 93% of patients had a favorable clinical outcome at 13.6-month clinical follow-up. On multivariable analysis, predictors of complete occlusion at last follow-up were complete occlusion at the end of the procedure (OR 3.53), whereas rupture, posterior-circulation location, width, and diameter < 2 mm independently reduced obliteration odds.

Conclusions

Endovascular coiling of VSAs provides high occlusion and excellent clinical outcomes with minimal morbidity. Anatomical complexity (ultra-small size, posterior circulation) and incomplete initial packing remain targets for technical optimization and prospective evaluation.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.