Oct 2026· European Heart Journal· Vol 47· 0 citations
TL;DR
The reverse remodeling was observed as early as 1-month post-implantation and continued to 1-year while no change of the diastolic parameters was noted, and consistent trends across subgroups such as baseline native RBBB and narrow QRS were confirmed.
Abstract
Left ventricular reverse remodeling and systolic function preservation have been demonstrated in patients with left bundle branch block (LBBB) who received left bundle branch area pacing (LBBaP). Less is known about the impact of LBBaP on patients with non-LBBB patterns, especially considering the iatrogenic RBBB pattern induced by LBBaP.
To explore the potential difference in alteration for left ventricular functional and geometric parameters after LBBaP in patients with LBBB and non-LBBB.
Consecutive patients receiving LBBaP for bradycardia with anticipated frequent ventricular pacing between 2017 and 2024 and followed up in a tertiary center were retrospectively reviewed. All participants underwent transthoracic echocardiography before the index implantation and in the scheduled 1-month, 3-month, 6-month, and 12-month follow-up. Pre-and post-implantation echocardiographic parameters were compared by paired t-test.
A total of 369 patients were analyzed, among whom 130 (35.2%) were females, and the average age was 73±12 years. The average baseline QRS width was 120±30ms,and 60 (16.3%) patients had a native LBBB pattern. Patients with LBBB had wider baseline QRS (152±18 vs. 114±28 ms) and QTc (489±48 vs. 450±45 ms) ,as well as larger LVEDD (5.3±1.0 vs. 4.7±0.6 cm) and lower LVEF (55.4±16.7 vs. 66.4±11.1 cm) than patients with non-LBBB, but similar diastolic parameters such as E/A, E/E’ ratio, and pulmonary artery systolic pressure (PASP). All the patients had LVEF preserved throughout the observation period. LBBaP led to decreased QRS widths (127±14 vs. 152±18 ms), QTc (473±38 vs. 489±48 ms), left atrial diameter (LAD) (3.9±0.6 vs. 4.1±0.6 cm), and LVEDD (5.0±0.9 vs. 5.2±0.9 cm) in patients with LBBB (all p<0.05). The reverse remodeling was observed as early as 1-month post-implantation and continued to 1-year while no change of the diastolic parameters was noted. LBBaP led to slightly increased QRS widths (117±18 vs. 114±28 ms), QTc (458±36 vs. 451±46 ms), decreased LAD (3.8±0.7 vs. 4.0±0.6 ms),and downward diastolic functional classification demonstrated by change of E/A (0.7±0.2 vs. 0.9±0.4), E/E’ (13.6±6.4 vs. 14.8±6.5), and PASP (31±8 vs. 36±12 mmHg) in patients with non-LBBB (all p<0.05). These changes were observed as early as 1-month post-implantation and continued to 1-year. Decreased LVEDD was observed on 3-month post-implantation (4.6±0.6 vs. 4.8±0.6 cm) and continued to 1-year. Subgroup analysis confirmed consistent trends across subgroups such as baseline native RBBB and narrow QRS, with and without structural heart disease.
Improvement of left ventricular diastolic function induced by LBBaP might be a unique benefit for patients with non-LBBB patterns. Our data support LBBaP as an important alternative or supplementary pacing strategies especially for patients who are not good candidates for biv-pacing resynchronization therapy.Diastolic function alteration in non-LBBB
Conduction system pacing has emerged as a novel alternative to conventional biventricular pacing in patients with heart failure requiring cardiac resynchronization therapy (CRT).
The aim of this study was to evaluate the rate of response and the degree of ventricular dyssynchrony in patients undergoing CRT...
J. Mizner, T. Knize, L. Povišer et al.· European Heart Journal· 0 citations
BACKGROUND
Left bundle branch area pacing (LBBP) has become a preferred as a novel strategy for cardiac resynchronization therapy (CRT). High-frequency QRS (HFQRS) analysis can detect subtle ventricular depolarization abnormalities that are not identifiable on standard electrocardiography and may provide novel markers...
Zhi-Hui Hou, Zhong-Wei Jiang, Xian-Kai Xia et al.· International Journal of Car...· 0 citations
Background: Left bundle branch block (LBBB) is frequently associated with structural heart disease and heart failure (HF) and is known to cause ventricular dyssynchrony, leading to impaired cardiac function. However, data regarding its impact on left ventricular systolic function in hospitalized HF patients remain limi...
Pappu Bhargava Raghavendra, J. Resident· International Journal of Dru...· 0 citations
BACKGROUND
The hemodynamic and mechanical benefit of left bundle branch area pacing (LBBAP) in heart failure with preserved ejection fraction (HFpEF) remained underexplored.
OBJECTIVES
The authors aimed to evaluate the hemodynamic and mechanical response of LBBAP in HFpEF population.
METHODS
This cohort study inclu...
Yang Su, Xiao-Xiao Xu, Dai-Han Xie et al.· JACC: Asia· 0 citations
Background/Objectives: Evidence on myocardial-work indices beyond 12 months after left bundle branch area pacing (LBBAP) remains limited. We compared global myocardial work efficiency (GWE) and the left ventricular ejection fraction (LVEF) after LBBAP and right ventricular mid-septal pacing (RVP). Methods: This prospec...
G. Leventopoulos, M. Bozika, P. Chronopoulos et al.· Journal of Clinical Medicine· 0 citations
Left bundle branch area pacing (LBBAP) is increasingly adopted for bradyarrhythmias due to stable pacing thresholds and potential prevention of pacing-induced cardiomyopathy. However, the clinical impact of its subtypes, namely left bundle branch pacing (LBBP) versus left ventricular septal pacing (LVSP), remains...
H. Kono, N. Oyanagi, H. Chinen et al.· European Heart Journal· 0 citations