Impact of Solar PV Integration on 33 kV Sub-Transmission Grid of Port Harcourt Distribution Network

2026 · International journal of research and scientific innovation · 0 citations

Abstract

This research work focuses on the impact of Solar Photovoltaic Integration into the 33 kV Sub-Transmission Grid of Port Harcourt Distribution Network. The global energy sector is experiencing a profound transition toward renewable energy, propelled by the need to address climate change, curb greenhouse gas emissions, and secure sustainable energy for the future. Six 500 kW Solar PV units were integrated at strategic locations, bus 5, bus 8, bus 10, bus 31, bus 36 and bus 40 of the Port Harcourt 132/33kV sub-transmission network having been observed to be operating under a critical under voltage conditions from the base case simulation results. Having obtained the simulation results for the six different cases of PV units’ placement, the overall comparison of the bus voltage profiles and power losses before and after the PV placements was done. By comparing with the network without PV units, the optimal installation of six PV units results in better average bus voltage levels from 0.90 per unit to 0.95 per unit and also raises the lowest voltage level in the system from 0.836 per unit to 0.88 per unit. Similarly, the six PV units' ideal placement reduced the overall actual and reactive power losses by (42606.8kW, 120286.10kvar) to (10140.42kW, 23515.93kvar) respectively, amounting to 76.20% and 80.45% reduction in the overall real and reactive power losses respectively. Minimizing power losses and improving voltage profiles are critical to the efficient operation of electrical distribution systems. The results also indicate that the integration of solar PV through solar inverters introduces voltage harmonics into the power system. However, the total harmonic distortion (THD) values remain below 5%, which does not pose any significant challenge on the network in accordance with the IEEE 519-2022 standard for medium voltage systems up to 33kV. The steady-state performance assessment was also performed in order to examine the impact of PV connection to PHED’s network under normal and contingency operating conditions. The assessment included the N-1 and N-2 contingency analysis to determine the network’s ability to maintain acceptable voltage profiles, loading levels, and overall system performance following the loss of one or two network elements. The results provide an indication of the network’s steady-state operating margin and its ability to withstand contingencies following PV integration. This study provides a comprehensive framework for assessing and improving solar PV integration, offering valuable insights and strategic recommendations for stakeholders. By addressing technical, regulatory, and infrastructural challenges, PHEDC can effectively harness the potential of solar PV systems, paving the way for a resilient and sustainable energy future.

Read PDF

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.