Off-Broadside Calibration of Polarimetric MIMO Radar Using Extended-GCT
Abstract
Accurate calibration of polarimetric multiple-input–multiple-output (MIMO) automotive radar becomes challenging under off-broadside beamforming, where existing calibration techniques suffer from angular inconsistencies because angle-dependent polarimetric basis distortion makes the recovered polarimetric scattering matrix (PSM) inconsistent across azimuth. This article proposes an extended generalized calibration technique (Extended-GCT) to address this limitation. The method uses the transmission and reception matrices estimated by the conventional generalized calibration technique (GCT) as initial estimates and refines them through a multiangle nonlinear least-squares optimization that enforces consistency of the recovered PSM of a reference target across azimuth. The approach is evaluated using both an analytical signal model and measurements from a 77-GHz polarimetric MIMO frequency-modulated continuous-wave radar with trihedral and dihedral reflectors over an azimuth range of 0°–60°. Practical studies further assess the effects of MIMO channel selection, channel averaging, and reducing the number of calibration angles. With channel-averaged measurements, Extended-GCT improves the measured minimum co-to-cross-polarized amplitude separation by 7.77 dB for the trihedral and 10.88 dB for the dihedral relative to conventional GCT. Moreover, using only four calibration angles retains gains of 5.71 and 6.40 dB, respectively, demonstrating the potential to reduce calibration effort while maintaining improved wide-angle polarimetric consistency.