Oct 2026· IEEE transactions on neural systems and rehabilitation engineering· Vol 34, pp. 4179-4189· 0 citations· 40 references
Medicine
TL;DR
A personalized gait phase estimation framework based on supervised domain adaptation (SDA) with a multi-phase maximum mean discrepancy (MP-MMD) objective that aligns source and target latent features separately during stance and swing using stride-specific toe-off labels is proposed.
Abstract
Accurate gait phase estimation is important for characterizing locomotor progression and enabling phase-dependent monitoring and intervention across gait analysis, rehabilitation, neuroprosthetic, and wearable assistive systems. However, this remains challenging in post-stroke individuals because pathological gait patterns vary substantially across subjects, while patient-specific gait data are often limited. To address this issue, this study proposes a personalized gait phase estimation framework based on supervised domain adaptation (SDA) with a multi-phase maximum mean discrepancy (MP-MMD) objective. This objective aligns source and target latent features separately during stance and swing using stride-specific toe-off labels. A shared feature extractor and domain-specific regressors are jointly trained using data from non-disabled individuals and limited labeled data from each post-stroke participant to construct a subject-specific model. Leave-One-Trial-Out evaluation of seven participants yielded a Root Mean Square Error (RMSE) of <inline-formula> <tex-math notation="LaTeX">$4.37 \pm 1.26\%$ </tex-math></inline-formula> and a Maximum Absolute Error (MaxAE) of <inline-formula> <tex-math notation="LaTeX">$8.64 \pm 1.90\%$ </tex-math></inline-formula>. After Holm correction, the proposed SDA method achieved significantly lower RMSE than Source Only and Fine-Tuning and lower MaxAE than all three baselines (all adjusted <inline-formula> <tex-math notation="LaTeX">$p=0.047$ </tex-math></inline-formula>). Relative to Target Only and Fine-Tuning, RMSE showed numerical reductions of 13.32% and 57.51%, respectively, and MaxAE decreased by 26.50% and 72.17%. Compared with conventional global MMD, MP-MMD yielded numerical reductions of 2.87% in RMSE and 2.77% in MaxAE. These results constitute a proof-of-concept for data-efficient within-subject personalization of gait phase estimation.
Gait assessment supports the diagnosis, monitoring, and prognosis of diverse movement-related conditions, such as neurological and musculoskeletal disorders. Recent advances in deep learning using everyday wearable inertial measurement units (IMUs) offer an accessible and low-cost approach to automated gait assessment....
Impairment resulting from stroke significantly affects patient mobility, making recovering the ability to walk a primary rehabilitation goal. While wearable inertial measurement units (IMUs) offer a cost-effective alternative to subjective clinical observations, conventional gait analysis often struggles with the high...
Conventional clinical assessments of stroke rehabilitation are limited to supervised environments and fail to capture continuous real-world motor behavior. This proof-of-concept pilot study (case series, n = 3) evaluated the feasibility and longitudinal sensitivity of wearable IMU-derived digital biomarkers of three in...
R. Soangra, Susan V. Duff, A. Mckenzie· Italian National Conference...· 0 citations
Surface electromyography (sEMG) provides a non-invasive measure of neuromuscular activity and is widely used for gait decoding in wearable and rehabilitation systems. Existing sEMG-based approaches rely on end-to-end supervised regression with dense kinematic labels, limiting scalability, generalization, and interpreta...
Chen Wang, Jia-Tong Cui, Liang Peng et al.· IEEE transactions on bio-med...· 0 citations
BackgroundGait impairment in dementia and Parkinson's disease (PD) contributes to falls, reduced mobility, and loss of independence. Sensor-integrated, AI-assisted gait training systems may provide standardized rehabilitation with real-time feedback and quantitative gait assessment.Objective: To investigate whether a s...
Chien-Tai Hong, Li-Kai Huang, Cheng-Hsing Liu et al.· Technology and Health Care· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.