Analysis of Echoic Conditions, Signal-to-Noise Ratio, and Angle of Arrival Effects on Active Phased Array Calibration
Abstract
This paper studies the impact of practical measurement constraints, namely echoic conditions, reduced signal-to-noise ratio (SNR), and limited calibration angles, on active phased array calibration. Three power-based techniques, single-channel sequential lobe steering (SCSLS), single-channel sequential null steering (SCSNS), and rotating electric-field vector (REV), are evaluated and compared using beam pattern metrics relative to an ideal array factor. Results show that sparse calibration angles degrade performance, with RMS error increasing by approximately 1.5% per 10° mismatch for all techniques. SCSLS exhibits slightly lower degradation but higher absolute root mean square (RMS) error. Calibration in quasi-echoic conditions performs comparably to anechoic scenarios. Additionally, all techniques exhibit an SNR threshold below which calibration fails, with no significant improvement beyond it.