Oct 2026· European Heart Journal· Vol 47· 0 citations
Abstract
On non-contrast cardiac CT (NCCT) images, the left ventricular (LV) myocardium and blood pool share nearly identical attenuation, rendering endocardial boundary delineation infeasible. Publicly available AI models trained on contrast-enhanced CT (CECT) have been applied to NCCT for LV mass estimation, but their segmentation accuracy on this fundamentally different modality has not been rigorously validated.
To develop and comprehensively evaluate ncLVMass-Net, a dedicated AI model for LV myocardium segmentation in NCCT, with respect to segmentation accuracy, LV mass estimation, subgroup consistency, and LV hypertrophy (LVH) detection.
CECT-based myocardial annotations from 1,529 patients were transferred to paired NCCT images through rigorous three-dimensional non-rigid registration with systematic quality verification, creating a large-scale training dataset with pixel-level ground truth. ncLVMass-Net was developed using the nnU-Net framework and evaluated against TotalSegmentator, MOOSE 3.0, and Mask R-CNN on internal (N=190) and external (N=308, three hospitals) testing sets. Performance was assessed for both thick- and thin-slice NCCT images.
ncLVMass-Net achieved a Dice similarity coefficient (DSC) of up to 0.88 in both internal and external testing, substantially outperforming TotalSegmentator (DSC: 0.78–0.83), MOOSE (DSC: 0.67–0.78), and Mask R-CNN (DSC: 0.74–0.77). For LV mass estimation, ncLVMass-Net achieved the lowest mean absolute error (internal: 4%; external: 6%), while other models demonstrated persistent over- or underestimation with errors exceeding 12%. ncLVMass-Net reduced bias magnitude by up to 91.5% and mean absolute error by up to 78.5% relative to CECT-trained models applied directly to NCCT. Unlike TotalSegmentator and MOOSE, which exhibited progressive underestimation with increasing LV mass, ncLVMass-Net demonstrated no mass-dependent bias and maintained consistent performance across subgroups dichotomized by LV size and myocardial volume (variation < 2.3% in mean absolute error). ncLVMass-Net achieved excellent agreement with ground truth (ICC > 0.9) and yielded a superior LVH detection F1-score of up to 0.9.
A dedicated AI model can achieve accurate myocardial segmentation and quantification from NCCT despite the invisible endocardial boundary. ncLVMass-Net substantially outperforms publicly available models in segmentation, LV mass quantification, and LVH detection, enabling reliable LV mass quantification and LVH detection from routine NCCT.Figure
Two-dimensional echocardiography is a widely adopted non-invasive medical imaging modality for the assessment of cardiac structure and function. However, manual delineation of cardiac boundaries remains a time-consuming task requiring substantial clinical expertise. This study presents a comparative evaluation of three...
Cardiac computed tomography (CCT) provides high-resolution data essential for personalized medicine and clinical evaluations; however, manual segmentation of cardiac structures is prohibitively time-consuming and prone to intra- and inter-observer variability.
To manually label a comprehensive, multi-cente...
P. M. Kazaj, L. Weber, W. Xie et al.· European Heart Journal· 0 citations
The approach enabled low-error NWU quantification from baseline NCCT without advanced imaging, supporting further prospective clinical evaluation and targeting NCCT-only infarct segmentation across heterogeneous external cohorts, although performance varied across domains.
Linus Britt, M. Nielsen, S. Klapproth et al.· arXiv.org· 0 citations
Objectives: Acute coronary syndrome (ACS), pulmonary embolism (PE), and aortic dissection (AD) present with overlapping symptoms but require markedly different treatments. We investigated whether cardiac quantitative parameters obtained by automated segmentation of non-contrast and contrast-enhanced chest CT can suppor...
Shuo Liang, Zhong-Yun Liu, Dan Li et al.· Medicina· 0 citations
Accurate delineation of cardiac structures in cardiac magnetic resonance (CMR) images is a prerequisite for quantifying cardiac function. This paper presents an end-to-end pipeline for automated cardiac segmentation and five-class pathology classification, evaluated on the 150 patients of the Automated Cardiac Diagnosi...
Alina Georgiana Badea, I. Tache, Lidia Băjenaru et al.· Future Internet· 0 citations
Heart failure frequently remains undiagnosed until advanced stages. Automated extraction of cardiac chamber volumes from routine CCTA may enable opportunistic identification of patients at risk of ventricular remodeling without additional imaging or radiation. However, large-scale validation studies against cardi...
H. Lind, J. Kragballe, F. Fossan et al.· European Heart Journal· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.