Investigation of the similarity space for the tested parameters indicated that MRI image artefact was the principle reason for similarity minima not corresponding to the correct registration, hence failure of gradient descent optimisation.
Abstract
Conflicts of interest:
No conflicts of interest
Funding:
Exeter NIHR Biomedical Research Centre (BRC)
Nonspecific low back pain (NSLBP) is highly prevalent, with a significant societal and personal impact, yet the underlying mechanisms remains largely unknown. Evidence suggests a role for altered mechanical function: from local tissue changes to altered coordination patterns. It is important to move beyond static imaging in NSLBP to understand possible dynamic processes. This presentation focusses on the development of image registration-based tracking of vertebral bodies in dynamic MRI images.
Ten healthy participants underwent imaging in a 3T Siemens Magnetom MRI scanner using HASTE and TRUFISP sequences. They flexed and extended their lumbar spines passively or actively. 30–40 frames were obtained per session.
Image-registration parameters tested were: cross-correlation vs. normalised mutual information similarity measures, and gradient descent vs. exhaustive search optimisation. Imaging preprocessing methods tested were: histogram matching, contrast stretching, difference of Gaussians (DOG), Gaussian blurring, and gradient filters: Sobel, Canny, Prewitt, Farid, Scharr and Roberts. Image registration results were visually assessed, and similarity space was inspected as a function of displacements and rotations.
Inspection of the similarity space for the tested parameters indicated that MRI image artefact (aorta and CSF) was the principle reason for similarity minima not corresponding to the correct registration, hence failure. Additionally, multiple local minima resulted in the failure of gradient descent optimisation. DOG was most successful at overcoming the problem of artefact along with a modified exhaustive search method.
Vertebral body tracking is possible in high-speed MRI images despite MRI image artefact. Future directions to reduce need for manual tuning of parameters will be presented.
Background and purpose Routine diagnostic magnetic resonance imaging is acquired without immobilisation, creating co-registration uncertainty with planning computed tomography. We quantified whether treatment-position imaging reduced bony-landmark co-registration error, and whether the benefit persisted after resamplin...
T. Itonaga, R. Mikami, M. Okubo et al.· Physics and Imaging in Radia...· 0 citations
Deformable image registration of lung CT remains challenging due to the coexistence of large global displacements and local sliding deformations induced by respiratory motion. Existing multi-level registration methods based on cost volumes (CVs) usually adopt a unified search strategy across different resolution levels...
Jia-Jia Liu, Yu-Jie Wang, Yin-Jie Su et al.· Physica Scripta· 0 citations
This study presents a proof-of-concept MLC tracking system for dynamic adaptation of the radiation treatment based on the real-time target localization facilitated by MRSIGMA on a 1.5 T MR-Linac.
Tian-Yu Yang, W. Donahue, Aniket Pramanik et al.· 0 citations
Abstract Medical image registration, encompassing both rigid and non-rigid transformations, plays a fundamental role in medical image analysis. Applications such as therapy planning, longitudinal disease analyses, and model-based segmentation benefit from the use of registration. While rigid registration suffices for a...
Elina Gastreich de Llanes, Melina Wördehoff, Lukas Förner et al.· Current Directions in Biomed...· 0 citations
Its high multi-center adaptability and stability in small-lesion segmentation make it suitable for cross-institutional promotion, providing reliable anatomical references for prognosis assessment, doctor-patient communication, and rehabilitation monitoring.
Jia-Tong Wang, Hong-Xun Cui, Yong-Hui Liu et al.· 0 citations
OBJECTIVES
Dental MRI provides soft-tissue contrast without ionising-radiation, but is susceptible to motion, particularly in paediatric imaging. Independent mandibular motion limits conventional single-rigid-model correction, while tailored strategies remain unexplored for dental MRI. We developed an automated, region...
Zi-Han Ning, R. Spin-Neto, Jonathan Davies et al.· Dento maxillo facial radiolo...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.