Cyber-resilient load frequency control of multi-area renewable power systems using HNN-based sliding mode control with V2G
Abstract
This study presents a novel load frequency control (LFC) architecture for multi-area power systems that incorporates photovoltaic (PV) generation, energy storage systems (ESS), and vehicle-to-grid (V2G) capabilities. The central contribution involves formulating a Hopfield neural network-integrated sliding mode controller (HNN-SMC) a configuration not previously explored within the context of multi-area LFC. The Hopfield neural network (HNN) serves as an embedded, real-time optimization engine within the sliding mode control law, deriving adaptive control gains by continuously minimizing a quadratic Lyapunov energy function with no dependency on pre-trained models. A redefined global fast terminal sliding surface incorporating a nonlinear, time-varying decay mechanism provides finite-time convergence in the nominal case and ultimate boundedness under bounded matched and mismatched disturbances satisfying Assumption 1 The EV-V2G component is treated as a stochastically available bidirectional energy resource, thereby expanding the frequency regulation potential beyond what PV-ESS configurations alone can offer. Furthermore, an HNN-based anomaly detection module is embedded within the control architecture, conferring resilience against cyber-threats, specifically communication delays, packet loss events, false data injection (FDI) attacks, and replay attacks. Closed-loop stability is rigorously substantiated using an augmented Lyapunov function. Validation through simulations on a two-area LFC benchmark and the IEEE 39-bus test network reveals that HNN-SMC achieves reductions of 81.1% in steady-state frequency error, 70.5% in settling time, and 43.7% in peak frequency deviation relative to a proportional-integral-derivative baseline (Area 1, 0.016 p.u. step disturbance); the corresponding margins over the stronger GFTSMC baseline under the same condition are smaller (42.1%, 38.2%, and 8.1% respectively), and over SMC are intermediate (72.4%, 66.8%, and 34.1%). When subjected to the most severe combined cyber-attack scenario involving simultaneous delays, packet loss, and FDI, the proposed cyber-secure HNN-SMC keeps frequency deviation within 0.245 Hz, versus 0.381 Hz for unprotected GFTSMC and 0.362 Hz for AGFTSMC under the identical worst-case scenario. The proposed scheme operates without offline training and delivers a computationally lean, robust, and cyber-secure solution for frequency governance in high-penetration renewable energy systems.