B-113 Comparison of Immunofixation Gel Methods and Immunotyping for Monoclonal Protein Characterization
Abstract
Characterizing monoclonal proteins is an important part of laboratory testing for monoclonal gammopathies. Key reasons include determining disease prognosis or progression and assessing complete response or minimal residual disease. Therefore, during implementation of a new method, the opportunity arose to compare two immunofixation gel electrophoresis methods and immunotyping (also termed immunosubtraction). Samples were analyzed for monoclonal characterization according to manufacturer instructions and laboratory policy using the Helena Laboratories SPIFE® ImmunoFix-9 kit (H-IFE), Sebia HYDRAGEL 9 immunofixation (S-IFE), and Sebia CAPI 3 IMMUNOTYPING (S-IT). The serum and urine samples included specimens with no expected monoclonal proteins, a single monoclonal protein, or multiple monoclonal proteins. Each protein type was documented individually, and multiples of the same type were counted separately (e.g., IgG kappa x2, free kappa x2). Artifact frequency associated with challenging interpretations was calculated for all samples, but those with no expected monoclonal proteins were excluded from concordance statistics due to perfect correlation. Concordance among all methods was measured using Fleiss’ kappa with bootstrapped 95% confidence intervals (CI), and pairwise concordance was evaluated with Cohen’s kappa. The statistical analyses were performed using Microsoft Copilot with Python packages including pandas, NumPy, scikit-learn, and matplotlib. One serum sample was excluded because S-IT results were missing. For the remaining serum samples (n=45), overall agreement among the three methods was good, with a Fleiss’ kappa of 0.79 (95% CI 0.70–0.88). Pairwise agreement was very good between H-IFE and S-IFE (Cohen’s kappa 0.86). Agreement between each IFE method and S-IT was also good (H-IFE vs S-IT: 0.74; S-IFE vs S-IT: 0.77). Only nine urine samples with monoclonal proteins were available for the three-way comparison, yielding a Fleiss’ kappa of 0.65 (95% CI 0.42–0.85). Pairwise Cohen’s kappas ranged from 0.60–0.70, with best agreement again observed between IFE methods. Additional urine samples allowed a two-way comparison of H-IFE and S-IT (n=27), yielding a Cohen’s kappa of 0.51 (95% CI 0.38–0.66). Typical artifacts were observed, including faint bands, isolated heavy or light chains, heavy polyclonal proteins obscuring monoclonal bands, and misaligned or complex immunotyping electropherograms. Artifacts occurred less frequently in serum than urine, likely due to protein fragmentation and variability in urine. In serum, artifact frequencies were H-IFE 10%, S-IFE 7%, and S-IT 8%. In urine, artifact rates were higher: H-IFE 44%, S-IFE 15%, and S-IT 12%. Reduced artifact rates with Sebia methods may reflect more standardized sample preparation, and H-IFE artifacts could potentially be reduced through further optimization. Limitations include a single interpreter, possible sample selection bias, few urine samples with monoclonal proteins tested by all three methods, and possible suboptimal optimization of H-IFE. Immunofixation and immunotyping methods compare well overall. Each method’s limitations can be offset by the strengths of the other, helping resolve challenging monoclonal protein interpretations. However, the higher artifact rate in urine samples makes H-IFE more challenging to interpret than S-IFE, and additional method optimization may help reduce this limitation.