Development and commutability assessment of serum-based candidate reference materials for homocysteine and their application in external quality assessment.
Jul 2026· Clinica chimica acta; international journal of clinical chemistry· Vol 592, pp.
121227
· 0 citations· 25 references
Medicine
TL;DR
In-house prepared serum-based Can-RMs and Ser-EQA materials exhibit excellent commutability, supporting reliable standardization assessment and accurate trueness validation for clinical procedures.
Abstract
Background
Elevated serum homocysteine (HCY) is associated with cardiovascular and other systemic risks. This study aimed to develop serum-based secondary candidate reference materials (Can-RMs) for metrological traceability and validating their dual utility as commutability-verified materials for external quality assessment (EQA).
Methods
First, 41 fresh serum samples were analyzed by isotope dilution liquid chromatography-tandem mass spectrometry reference method and four routine detection systems to evaluate baseline comparability. Second, the commutability of Can-RMs, EQA materials spiked with purified reference standards (Sta-EQA materials), and in-house prepared EQA materials with serum matrix (Ser-EQA materials) was assessed via Deming regression and bias analysis. Third, the commutable Can-RMs were deployed in a 62-laboratory EQA program; performance (CV, bias, total error) were evaluated per biological variation-based minimum analytical quality specifications (6.23%, 12.94%, and 23.21%).
Results
Routine systems exhibited positive proportional biases (0.5%-13.1%) versus the reference method. The Can-RMs (L1-L5) and Ser-EQA materials were commutable across all systems (with only Can-RM L1 for the Leadman system was inconclusive under IFCC criteria). All Sta-EQA materials were non-commutable under both approaches. In the EQA program, the average laboratory pass rates for TE, bias, and CV were 91%, 87%, and 98%, respectively, with the Roche and Strong Biotechnologies systems achieving 100% pass rate.
Conclusions
In-house prepared serum-based Can-RMs and Ser-EQA materials exhibit excellent commutability, supporting reliable standardization assessment and accurate trueness validation for clinical procedures. A major limitation is that all reagents were tested on a single Roche Cobas c701 analyzer; future multi-instrument trials are required to verify generalizability.
Abstract Objectives Clinical interpretation of ferritin is hindered by between-assay differences, persisting despite the introduction of different generations of WHO standard. To aid harmonisation efforts, this study investigates the commutability of External Quality Assessment (EQA) materials, proof-of-concept referen...
M. M. Bioch, R. Schoeman, C. Weykamp et al.· Clinical Chemistry and Labor...· 0 citations
AIM
Lipoprotein(a) [Lp(a)] is an independent risk factor for cardiovascular disease (CVD); however, the goal of resolving its measurement issues remains unachieved. Expanding on the "first step" by Miida et al., this study evaluated the feasibility of harmonizing Lp(a) measurements using an IFCC endorsed mass spectrome...
Keita Yamashita, Mitsuru Wakita, Noriyasu Niizeki et al.· Journal of atherosclerosis a...· 1 citation
Data shows that the microbiological method, LC-MS/MS and Tosoh CL1200 immunoassay have acceptable accuracy, imprecision and agreement, and the small concentration dependant bias is likely explainable by the expected characteristics of the individual methods and ability to detect and respond to different forms of folate...
Sarah R Meadows, Amanda McKillion, Damon A. Parkington et al.· Annals of Clinical Biochemis...· 0 citations
Introduction Biomonitoring of commercial endocrine-disrupting chemicals (EDCs) increasingly underpins exposure assessment and risk evaluation, yet most large-scale studies still rely on indirect, enzymatic hydrolysis–based methods whose quantitative performance has not been systematically verified. Here, we describe th...
R. Gerona, Alia Sovereign, Patricia Hunt· Frontiers in Chemistry· 0 citations
Findings indicate that this isotope-based surrogate analyte approach eliminates the need for calibration curves, compensates for matrix effects and sample preparation errors, and improves analytical reliability and efficiency across biological matrices.
Zeinab Srour, Farzad Kobarfard, Zahra Sheikholislam et al.· Iranian journal of pharmaceu...· 0 citations
BACKGROUND
Fully automated liquid chromatography-tandem mass spectrometry (LC-MS/MS) platforms aim to combine the analytical specificity and sensitivity of mass spectrometry with the workflow efficiency of automated routine analyzers. This study performed a preliminary analytical evaluation of the Cobas i601 LC-MS/MS s...
Mariana Serres-Gómez, María Luisa González-Casaus, María Gemma Serrano Olmedo et al.· Clinica chimica acta; intern...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.