Investigation of the gas-liquid distribution and performance in anion exchange membrane electrolyzers
Abstract
ABSTRACT An anion exchange membrane (AEM) electrolyzer with a 1.4 mm-wide single-serpentine flow field was developed to investigate the in-situ coupling between performance inhomogeneity and gas-liquid two-phase flow. Bubble coverage, flow-pattern distribution, and migration velocity were quantified to evaluate the effects of operating conditions on two-phase transport and electrochemical performance. The results reveal pronounced local performance variations induced by the spatiotemporal evolution of two-phase flow. Increasing temperature enhances performance by accelerating electrode kinetics and reducing activation and ohmic losses, whereas higher electrolyte flow rates alleviate mass-transfer limitations at high current densities through enhanced liquid-phase drag, with diminishing performance gains. Under high loads, long gas segments dominate the 1.4 mm channel and increase mass-transfer resistance, while a spatial saturation node at 0.4 A/cm2 marks the transition from distribution expansion to compositional reconstruction. Transient tests show an immediate voltage response to current steps. Bubble tracking further reveals local acceleration at U-turns, whereas migration velocity decreases away from the outlet due to energy dissipation and localized congestion caused by bubble coalescence and collisions in the middle flow-field region.