Skip to content

Experimental Investigation of Pressure Gradient Behavior in Two and Three-Phase Flow Through Horizontal Pipe and Annular Geometries

Nov 2026 · ADIPEC · 0 citations · 17 references

Abstract

Understanding the complex behavior of multiphase flow and its associated pressure gradients remains a critical challenge not only for flow assurance and production system design but also for ensuring process safety across industrial operations. This study investigates pressure gradient characteristics in both pipe and annular geometries under two- and three-phase flow conditions, through experimental evaluation and transition-metric analysis. Experiments were conducted using an advanced multiphase flow facility comprising horizontal pipe and annular flow loops, each with a 2 in. [5.08 cm] hydraulic diameter. The pipe loop is 23.8 ft [7.25 m] long and the annular loop is 20.2 ft [6.16 m] long. Air-water, air-biopolymer (non-Newtonian), and air-water-oil tests were performed across both geometries, covering superficial liquid velocities of 3.38 to 10.53 ft/sec [1.03 to 3.21 m/s] in the pipe and 1.00 to 3.25 ft/sec [0.30 to 0.99 m/s] in the annulus, and gas injection rates of 0.07 to 1.125 ft/sec [0.020 to 0.343 m/s]. Dynamic and differential pressure sensors recorded high-frequency pressure signals across 530 dynamic-channel experiments and 335 differential-channel experiments. Three-phase (air-water-oil) flow produced modestly lower fluctuation amplification than air-water flow in the pipe on the ramp-insensitive estimator, spanning 0.52 to 1.00 against 0.70 to 1.53 at matched conditions, with a smaller onset step at the highest gas rate, consistent with oil moderating the frictional response. The annulus settled approximately 27 times faster than the pipe upon gas injection (0.26 s against 6.90 s at matched conditions, preserved in 94 percent of matched pairs) but with a substantially smaller differential pressure gradient step (approximately 0.053 psi/100 ft [1.2 × 10-4 bar/m] against 3.5 psi/100 ft [8.0 × 10-3 bar/m]), and with mean gradient response to gas that was not resolved above the instrument noise floor, indicating that the transient channel rather than the steady-state channel is the appropriate basis for annular gas detection. For non-Newtonian flow, geometry exerted a stronger influence than fluid concentration. The pipe exhibited greater fluctuation amplification than the annulus on the ramp-insensitive estimator, while varying biopolymer concentration produced no consistent effect in the annulus and only modest effects in the pipe, confirming that geometric confinement governed two-phase behavior more strongly than rheology. This study provides one of the first systematic comparisons of pressure transient behavior in both pipe and annular geometries under two- and three-phase conditions at matched hydraulic diameter. By extending the conventional gas-water system to include gas-water-oil and air-non-Newtonian mixtures and by reporting two complementary fluctuation estimators that isolate the level-change and intermittency contributions separately, we establish that the annular geometry is faster and quieter in steady state but comparable to the pipe in its arrival-event detectability at matched gas mass rate. The results offer practical guidance for the design of gas ingress detection schemes in managed pressure drilling and annular riser applications, where the geometry precludes mean-gradient monitoring but does not preclude transient detection.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.