Skip to content
Review

Abstract 8815: Accuracy of Explainable Multimodal Artificial Intelligence-Enhanced 12-Lead Electrocardiography for the Early Screening of Pulmonary Hypertension: A Systematic Review

Nov 2026 · Circulation · 0 citations

Abstract

Background: Pulmonary hypertension (PH) is a progressive disorder associated with substantial morbidity and mortality. It is often diagnosed late because of nonspecific symptoms. Current screening methods include right heart catheterization and echocardiography, both of which are invasive and resource-intensive. Artificial intelligence (AI)-enhanced electrocardiography has emerged as a promising noninvasive approach for early PH detection. We conducted a PRISMA-compliant systematic review to evaluate the diagnostic accuracy and explainability of multimodal AI-enhanced 12-lead electrocardiography for early PH screening. Methods: We searched PubMed, Embase, Scopus, Web of Science, and the Cochrane Library from January 2019 to May 2026. Human studies evaluating AI/ML/DL-enhanced 12-lead ECG models for PH or elevated pulmonary pressure and reporting diagnostic performance metrics were included. Extracted data included study characteristics, AI models, multimodal inputs, explainability methods, and diagnostic performance. Risk of bias was assessed using QUADAS-2.(PROSPERO: CRD420261412659) Results: Six studies involving approximately 30,000 participants met the inclusion criteria. Most of these were retrospective and used right heart catheterization or echocardiography as reference standards. AI-enabled ECG models achieved AUROC values of 0.88-0.92, sensitivities of 0.79-0.87, and specificities of 0.79-0.84, with acceptable performance up to 2-5 years before diagnosis (AUROC ≥0.79). On combining ECG with chest radiography and BNP, AUROC increased to 0.872 and increased cardiologist accuracy from 65% to 74%. Models that integrated imaging and clinical data further improved specificity and negative predictive value. Key predictors identified by explainability methods include ECG conduction/repolarization patterns and right-heart imaging features. Common limitations included retrospective design, heterogeneous PH definitions, and limited external validation. Conclusions: Explainable multimodal AI-enhanced ECG demonstrates high diagnostic accuracy for early PH screening and may identify disease years before conventional diagnosis. Integration with imaging and biomarkers further improves performance. Prospective multicenter validation and standardized reporting are needed before routine clinical implementation.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.