Volume-adjusted myocardial work, a novel diagnostic and prognostic tool in subtypes of aortic stenosis
Abstract
Aortic stenosis (AS), the most prevalent valvular heart diseases in developed nations, primarily affects elderly, multimorbid patients. With the increasing availability of valvular interventions, the proper evaluation of cardiac function remains a key question in both diagnosis and patient management. Conventional echocardiographic parameters, including ejection fraction (EF) and global longitudinal strain (GLS), are strongly influenced by loading conditions and may not accurately reflect left ventricular (LV) contractility in cases of hemodynamic overload. Although pressure–strain loop–derived myocardial work partially addresses these limitations, it does not account for preload and LV geometry. Data on dedicated AS subtypes, particularly paradoxical low-flow low-gradient (pLFLG) AS, remain limited. We aimed to introduce pressure–strain–volume (PSV) loop–derived, volume-adjusted myocardial work and to evaluate its diagnostic and prognostic value in patients with severe AS undergoing transcatheter aortic valve replacement (TAVR). We enrolled 300 patients with severe AS undergoing TAVR (age 78.7±6.3 years, 41% female). Preprocedural echocardiography and non-invasive blood pressure measurements were performed a day before the intervention. EF and LV volumes were assessed using the biplane Simpson method, and GLS was obtained by speckle-tracking. LV pressure curves were estimated from cuff blood pressure and the Doppler-derived transaortic gradient. Global constructive work (GCW) was calculated from pressure–strain loops and then further adjusted to instantaneous LV volumes to derive volume-adjusted GCW (GCWVi). Patients were classified as normal-flow high-gradient (NFHG), classical low-flow low-gradient (cLFLG), or pLFLG in accordance with current guidelines. The endpoint was all-cause mortality, reached by 62 patients during a median follow-up time of 25 months. GCW was comparable between NFHG and pLFLG but reduced in cLFLG (1583 ± 459 vs. 1378 ± 535 vs. 967 ± 470, p < 0.001). In contrast, GCWVi was significantly lower in both cLFLG and pLFLG compared with NFHG (5.04 ± 2.03 vs. 5.79 ± 1.87 vs. 6.72 ± 2.35). Kaplan–Meier analysis demonstrated improved survival in patients with GCWVi above the median in the overall cohort (p = 0.017) and in those with preserved EF (p = 0.007). The novel PSV-loop derived myocardial work measure had shown a significant difference in subtypes of aortic stenosis and had prognostic value in patients undergoing TAVR. As such volume-adjusted global constructive work may have the potential to more accurately measure LV contractility in a hemodynamic overload state. This novel approach may improve functional assessment and risk stratification in patients undergoing TAVR.GCWVi bar graph