Skip to content

The Early Stability of Short vs. Standard Dental Implants with Identical Shallow-Thread in the Posterior Region of the Mandible: A Prospective Pilot Study.

Aug 2026 · The International Journal of Oral and Maxillofacial Implants · Vol 0 0, pp. 1-36 · 0 citations
Medicine

TL;DR

Within the constraints of this small, nonrandomized pilot, 7-mm shallow-thread implants in D2-D3 bone demonstrated primary stability that was descriptively similar to 11-mm implants, providing effect-size estimates and testable hypotheses for future adequately powered randomized trials rather than practice-changing guidance.

Abstract

Background

Short dental implants are a less invasive alternative for the limited posterior mandible, but their early stability dynamics remain unclear compared to standard implants.

Purpose

This prospective, non-randomized observational pilot study aimed to explore and descriptively compare early stability patterns (primary stability, stability dip, and recovery) between 7 mm short implants and 11 mm standard shallow-thread implants in the posterior mandible, treating implant length as the only design variable.

Materials And Methods

Ten patients received 20 implants (10 short, 10 standard) based on anatomical feasibility. Implant stability quotient (ISQ) was measured immediately post-implant placement (T0) and at the end weeks 1, 2, 3, and 5 (T1-T4). Insertion torque (ITV) was recorded. Linear mixed models (LMM) with patient random intercepts were the primary analysis. Bonferroni correction (α=0.005) was applied for 10 post-hoc comparisons. Bone density (D2/D3) by calibrated CBCT-HU.

Results

Primary stability (ITV and ISQ at T0) was similar between groups. Short implants showed nominal trends toward a larger dip magnitude (9.2±4.4 vs 5.9±2.3 ISQ units) and greater recovery (4.8±2.4 vs 2.6±2.2), but after Bonferroni correction none of the between-group comparisons at individual time points or intervals remained statistically significant (all p > 0.005). Bone density (D2 vs D3) had a statistically significant and clinically dominant effect on absolute ISQ at all times (LMM p<0.001). In the short-implant group, a moderate negative correlation between baseline ISQ and dip magnitude (r≈0.54) had wide confidence intervals that crossed zero and did not reach conventional statistical significance, and is therefore considered exploratory.

Conclusions

Within the constraints of this small, nonrandomized pilot, 7-mm shallow-thread implants in D2-D3 bone demonstrated primary stability that was descriptively similar to 11-mm implants. Apparent differences in dip and recovery did not remain statistically significant after correction for multiple comparisons and should be interpreted as hypothesis-generating only. However, bone density exerted a greater influence on early ISQ than implant length. These observations provide effect-size estimates and testable hypotheses for future adequately powered randomized trials rather than practice-changing guidance.

View source

Similar papers

Open access Oct 2026

Short Dental Implants as Strategic Support for Removable Partial Dentures in Mandibular Free-End Situations: A 3-Year Prospective Cohort Study.

OBJECTIVES This study aimed to assess the mid-term clinical performance of short implants as strategic support for mandibular removable partial dentures (RPDs) with free-end situations. METHODS Subjects wearing lower RPDs in Kennedy Class I situations received two supporting posterior implants. After the healing phas...

M. Fonseca, S. Abou-Ayash, Simone F. M. Janner et al. · 0 citations
Open access Oct 2026

Marginal bone level changes and soft-tissue esthetics around implants with convergent transmucosal profiles: 10-year retrospective analysis

The aim of this retrospective study was to analyze the long-term stability of marginal bone levels (MBL) and the Pink Esthetic Score (PES) in a cohort of patients treated with tissue-level implants featuring a convergent transmucosal profile. A retrospective longitudinal analysis was conducted on 108 patients who recei...

Nicola Alberto Valente, Gabriele Caruso, Nicola Carrus et al. · 0 citations
Aug 2026

Eight-Year Follow-Up of Hybrid and Moderately Rough Implants Supporting a Mandibular Overdenture: A Split-Mouth Randomized Clinical Trial.

This split-mouth randomized controlled trial evaluated the effect of implant surface roughness (hybrid vs. moderately rough) on long-term crestal bone remodeling and peri-implant health. Oral Health-related Quality of Life (OHRQoL) was evaluated after 1 and 8 years. Twenty-four fully edentulous patients received a mand...

S. Matthijs, Maarten Gilbert, Ruben Tilburgh et al. · 0 citations
Aug 2026

Proximal Peri-implant Bone Behavior in Immediately Loaded Extra-Narrow Dental Implants: Retrospective Cohort Study.

PURPOSE To evaluate the proximal bone behavior and 1-year survival rate of immediately loaded Ø2.9 mm narrow-diameter implants. MATERIALS AND METHODS Eighteen immediately loaded implants were retrospectively assessed by standardized radiographic analysis at three time points: T1, immediately after placement; T2, 4-6...

Hiromi Ikeda, Jean Ulhendorf, Ana Toyofuku et al. · 0 citations
Open access Sep 2026

Finite Element Analysis of Ultra-Short, Extra-Short, and Conventional Dental Implants in Fibula Free Flap Mandibular Reconstruction

Dental rehabilitation of fibula free flap mandibular reconstructions can be limited by the reduced vertical bone height available for implant placement. This study evaluated the biomechanical influence of ultra-short, extra-short, and conventional implants in a reconstructed fibula. Methods: A patient-specific finite e...

Mario Ceddia, Luciano Lamberti, Bartolomeo Trentadue · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.