60 Quantitation of Enterovirus D68 Clades A2, B1, B2, and B3 in Pediatric Respiratory Samples Using Digital PCR
Abstract
Enterovirus D68 (EV‑D68) is known to cause severe respiratory illness and trigger asthma exacerbations in children. In addition, EV‑D68 infection has been associated with acute flaccid myelitis (AFM), a rare but severe post‑infectious neurological condition that primarily affects children. Community outbreaks of EV‑D68 have been linked to clusters of AFM cases, and early detection of EV‑D68 circulation is important for raising awareness and supporting timely recognition of AFM. Digital PCR (dPCR) is an assay used to quantify the amplicon in a sample, allowing for increased sensitivity and accuracy. The objective of this study was to develop a dPCR assay capable of detecting multiple EV‑D68 clades and to quantify EV‑D68 viral loads in clinical samples to support assessments of disease severity, as well as to measure EV‑D68 levels in wastewater eluates to aid in predicting future community outbreaks. We tested linearity of dPCR using five-fold serially diluted stock viruses of EV-D68 A2, B1, B2 and B3 clades and compared with real-time RT-PCR detection. Similarly, EV-D68 positive nasopharyngeal swab samples collected from children (n = 29) in our hospital were tested using dPCR and RT-PCR. The real-time RT-PCR detected all the five-fold serially diluted clades A2, B1, B2 and B3 to dilution 4 with Ct values of 36.6, 36.6, 37.6 and 37.4 respectively at dilution 4. The dPCR also had similar detections to dilution 4 for all B clades (B1 at 3735, B2 at 2561, B3 at 1803 copies/mL) but better detection of clade A2 to dilution 5 (A2 at 1643 copies/mL). The coefficient of determination between the Ct values and Log10values of dPCR copies/mL was high for all serially diluted clades with A2 (R2=0.9445), B1 (R2=0.9543), B2 (R2=0.9876), and B3 (R2=0.9845). 26 of the 29 (90%) respiratory clinical samples were detected by dPCR (1,716 to 18,577,134 copies/mL) with an average of 5,714,514 copies/mL and median 718,055 copies/mL. The coefficient of determination (R2=0.82) was high between Ct values of RT-PCR and Log10values of dPCR copies/mL in clinical samples. Two samples that failed in dPCR had low Ct values of 21.7 and 21.9, suggesting high viral load beyond upper limit of dPCR, and one sample had Ct value of 27.1 that failed to detect in dPCR. The EV-D68 dPCR did not cross react with eight other enterovirus strains and rhinoviruses that were tested for specificity. Overall, dPCR is comparable to RT-PCR for reproducible detection across multiple clades of EV-D68 while being strain specific. Moreover, dPCR provides valuable information about viral load and may help assess infection severity, while also enhancing wastewater surveillance efforts aimed at predicting future EV‑D68 community outbreaks.