Skip to content

MedSegBenchmarker: A Raw-Count-First Framework for Controlled 2D Medical Image Segmentation Benchmarks

Aug 2026 · 1 citation · 51 references
Computer Science

TL;DR

MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.

Abstract

Despite rapid advances in MIS, fair and reproducible comparisons of segmentation models remain challenging due to heterogeneous datasets, inconsistent evaluation protocols, and rapidly evolving architectures. In particular, comparisons often implicitly assume that model rankings are invariant to data partitioning, preprocessing, metric aggregation, uncertainty estimation, and computational constraints. The lack of extensible and unified evaluation frameworks further limits systematic investigation of new models, datasets, and training paradigms. We present MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS. It integrates duplicate and near-duplicate image detection, group-aware data splitting, YAML study specifications, resumable training, hyperparameter optimization, cross-validation, and checkpoint-based evaluation. Rather than retaining only aggregate performance measures, MSB exports sample- and class-level pixel counts and predictions together with the evaluation context. These elementary artifacts enable post-hoc analyses without repeated inference. We demonstrate MSB in a case study involving three heterogeneous 2D datasets and multiple MIS and general-purpose vision models evaluated at 256- and 512-pixel input resolutions. Reaggregation of identical predictions changes the top-ranked architecture in three of six dataset-resolution settings, despite high rank correlations between aggregation strategies. Increasing input resolution produces model- and dataset-dependent performance gains and losses that must be considered alongside empirically measured inference complexity. These results show that seemingly minor choices in evaluation and experimental setup can affect benchmark conclusions. MSB, available at GitHub, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.

View source

Similar papers

Review Open access Oct 2026

A Survey on U-Net with Variants and Their Applications in Two-Dimensional Medical Image Segmentations

Medical image segmentation plays a critical role in computer-assisted diagnosis, treatment planning, surgical navigation, and quantitative medical image analysis. Among deep learning-based segmentation architectures, U-Net has become one of the most influential frameworks because of its encoder–decoder structure and sk...

Tian-Hui Wu, Shamsher Ullah, Bo-Chen Yu et al. · 0 citations
Aug 2026

TextBraTS: Bridging 3D MRI, Text, and Genotype for Data-Efficient Glioma Segmentation and Analysis.

This work quantifies the "Semantic Gain" of structured textual priors as a proof-of-concept, providing a controlled benchmark for the potential of structured text guidance and providing a robust foundation for integrated radiogenomic analysis and computer-aided diagnosis research.

Xiao-Yu Shi, Rahul Kumar Jain, Yinhao Li et al. · 0 citations
#artificial intelligence Preprint Sep 2026

Pre-training, Reasoning, Benchmarking: X-ray Report Generation on CheXpert Plus Dataset

X-ray image-based Radiology Report Generation (RRG) constitutes a critical research direction within medical artificial intelligence, with great potential to alleviate clinicians'diagnostic workload and shorten patient waiting periods. Despite substantial advances over recent years, the field faces evident bottlenecks...

Xiao Wang, Yu-Xiang Zhang, Dan Xu et al. · 0 citations
Preprint Sep 2026

When Online Adaptation Hurts: Parameter-Frozen Test-Time Ensembling for Continual Medical Image Segmentation

Medical image segmenters often get worse when sites, scanner vendors, or protocols change. Continual test-time adaptation (CTTA) addresses this problem without target labels, but it can be impossible to update a model on a non-stationary stream and can lead to a lot of errors. We examine a more reasonable and meaningfu...

Rui-Jie Huang · 0 citations
Open access Sep 2026

Uncertainty-guided decoupled complementary network for binary semi-supervised medical image segmentation

Semi-supervised medical image segmentation methods have drawn wide attention as they reduce reliance on heavily annotated data. However, existing models suffer from confirmation bias with limited annotations, and structural or parameter coupling hinders self-correction, especially for medical images with ambiguous boun...

Dong-Sheng Wang, Xiao-Han Lang · 0 citations

Related blog posts

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.