MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.
Abstract
Despite rapid advances in MIS, fair and reproducible comparisons of segmentation models remain challenging due to heterogeneous datasets, inconsistent evaluation protocols, and rapidly evolving architectures. In particular, comparisons often implicitly assume that model rankings are invariant to data partitioning, preprocessing, metric aggregation, uncertainty estimation, and computational constraints. The lack of extensible and unified evaluation frameworks further limits systematic investigation of new models, datasets, and training paradigms. We present MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS. It integrates duplicate and near-duplicate image detection, group-aware data splitting, YAML study specifications, resumable training, hyperparameter optimization, cross-validation, and checkpoint-based evaluation. Rather than retaining only aggregate performance measures, MSB exports sample- and class-level pixel counts and predictions together with the evaluation context. These elementary artifacts enable post-hoc analyses without repeated inference. We demonstrate MSB in a case study involving three heterogeneous 2D datasets and multiple MIS and general-purpose vision models evaluated at 256- and 512-pixel input resolutions. Reaggregation of identical predictions changes the top-ranked architecture in three of six dataset-resolution settings, despite high rank correlations between aggregation strategies. Increasing input resolution produces model- and dataset-dependent performance gains and losses that must be considered alongside empirically measured inference complexity. These results show that seemingly minor choices in evaluation and experimental setup can affect benchmark conclusions. MSB, available at GitHub, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.
Medical image segmentation plays a critical role in computer-assisted diagnosis, treatment planning, surgical navigation, and quantitative medical image analysis. Among deep learning-based segmentation architectures, U-Net has become one of the most influential frameworks because of its encoder–decoder structure and sk...
Tian-Hui Wu, Shamsher Ullah, Bo-Chen Yu et al.· Journal of Imaging· 0 citations
This work quantifies the "Semantic Gain" of structured textual priors as a proof-of-concept, providing a controlled benchmark for the potential of structured text guidance and providing a robust foundation for integrated radiogenomic analysis and computer-aided diagnosis research.
Xiao-Yu Shi, Rahul Kumar Jain, Yinhao Li et al.· IEEE journal of biomedical a...· 0 citations
X-ray image-based Radiology Report Generation (RRG) constitutes a critical research direction within medical artificial intelligence, with great potential to alleviate clinicians'diagnostic workload and shorten patient waiting periods. Despite substantial advances over recent years, the field faces evident bottlenecks...
Xiao Wang, Yu-Xiang Zhang, Dan Xu et al.· 0 citations
Multi-dimensional lightweight modules can reconcile segmentation quality with strict computational budgets when adapting video-centric foundation models to 2D clinical data.
Xue-Jia Yuan, Zong-Jian Yang, Yu Guo et al.· IEEE transactions on bio-med...· 0 citations
Medical image segmenters often get worse when sites, scanner vendors, or protocols change. Continual test-time adaptation (CTTA) addresses this problem without target labels, but it can be impossible to update a model on a non-stationary stream and can lead to a lot of errors. We examine a more reasonable and meaningfu...
Semi-supervised medical image segmentation methods have drawn wide attention as they reduce reliance on heavily annotated data. However, existing models suffer from confirmation bias with limited annotations, and structural or parameter coupling hinders self-correction, especially for medical images with ambiguous boun...
Dong-Sheng Wang, Xiao-Han Lang· Biomedical engineering and p...· 0 citations
Known for his clear and elegant writing style, Bertsekas shaped fields from control and optimization to large-scale computation and artificial intelligence.