Jul 2026· Journal of Applied Dentistry and Oral Sciences· Vol 12, pp. 128 - 136· 0 citations· 29 references
TL;DR
Full-arch intraoral scanning of edentulous models demonstrated clinically acceptable accuracy, within the limitations of this in vitro study, and should be interpreted cautiously when extrapolating to clinical intraoral conditions.
Abstract
Introduction This in vitro study assessed the accuracy of full-arch edentulous impressions obtained via intraoral scanning using various scanning strategies. This study aimed to evaluate whether the addition of surface markers would enhance scan precision in various anatomical regions of edentulous models, particularly on low-feature and smooth surfaces. Materials and Methods Sixty scans (30 maxillary and 30 mandibular) were performed using an intraoral scanner across three scanning protocols: unmodified (control), composite-resin, and drawn-line markers. Reference scans were obtained using a laboratory scanner. Scans were evaluated in four anatomical regions: the vestibule, residual ridge, palate/lingual area, and overall surface. Deviations were measured using the root mean square, mean deviation, and standard deviation. Two-way analysis of variance, with Tukey’s post hoc test, was used for the statistical analysis. Results The scanning strategy had no significant effect on the residual ridge area (p = .918). The jaw type significantly affected the scanning accuracy in all areas (p < .001), with greater deviations observed in the mandibular scans. Composite-resin and line marker strategies increased the accuracy in the mandibular vestibular and lingual regions. All root mean square error values remained within the clinically acceptable limits, although the numerical differences between the groups were minimal. Conclusion Full-arch intraoral scanning of edentulous models demonstrated clinically acceptable accuracy, within the limitations of this in vitro study. Surface markers did not provide a significant advantage in the maxillary scans but may improve scanning performance in mandibular regions. These findings provide methodological insights into scanning performance on smooth and low-feature surfaces and should be interpreted cautiously when extrapolating to clinical intraoral conditions.
Variations in arch form may influence the accuracy of digital impressions for implant-retained fixed dental prostheses. Differences in arch width, curvature, and span length can affect scanning continuity and data stitching, potentially impacting trueness and precision during full-arch acquisition. However, the extent...
M. S. Torky, Rewaa G. AboElhassan, Amir S. Azer· BMC Oral Health· 0 citations
Purpose This in vivo study aims to investigate the deviation of the residual ridge between digital and conventional impressions in the partially edentulous maxilla. Methods Forty-four patients (22 female, 22 male; 64.8 ± 6.6 years) with partially edentulous maxillae were included in the study. Digital impressions were...
Background: To evaluate the accuracy and precision of digital dental
impressions using the Polygon File Format (PLY) across three intraoral
scanners.
Methods: A maxillary arch resin model with reference points was scanned
10 times using the intraoral scanners (3Shape TRIOS 5, Medit i900, Cameo
Elegant 3) and a laborato...
Saud J. Dizayee· European Journal of Prosthod...· 0 citations
This in vitro study evaluated whether the presence of four remaining teeth affected the reproduction of interabutment spatial relationships by two intraoral scanning systems. A single three-dimensionally printed maxillary master model containing four implant analogues connected to Mini Conical Abutments was evaluated s...
Lucas David Galvani, Kathleen Lemos Soares, Jailson Junior Rodrigues Oliveira et al.· Applied Sciences· 0 citations
Within the limitations of this in vitro study, the RSB protocol demonstrated accuracy comparable to the SCB protocol, with more stable implant position transfer in four-implant configurations and a high clinical passive fit rate, supporting its use as a reliable alternative in complete-arch digital implant workflows.
Rabia Kilicaslan Dasdelen, İkbal Leblebicioğlu Kurtuluş, K. Kılıç· Journal of Prosthodontics· 0 citations
Copings fabricated from dies scanned using IOS demonstrated significantly lower vertical marginal discrepancies compared to those scanned using the laboratory scanner, however, the marginal gaps observed in both groups were within clinically acceptable limits.
P. S. Prakhyath, B. Prabhu, Shijal Narayan Suvarna· The Journal of Indian Prosth...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.