Digital workflow for implant-supported restorations in the mandible including reverse scan bodies: a feasibility study

Aug 2026 · BMC Oral Health · Vol 26 · 0 citations · 54 references
Medicine

TL;DR

Within the limitations of this single-patient evaluation and the favorable two-implant mandibular configuration, intraoral scanning provided sufficient accuracy for fabricating passively fitting restorations on two implants in the edentulous mandible.

Abstract

Completely edentulous mandibles present a challenge for accurate intraoral scanning, which can compromise the passive fit of implant-supported restorations. Reverse scan bodies may improve the accuracy of implant position transfer and support a fully digital workflow. However, clinical evidence for their use in the edentulous mandible remains limited. In this single-patient prospective clinical evaluation, one fully edentulous mandible restored with two interforaminal implants was scanned ten times using an intraoral scanner (IOS). Based on each scan, titanium verification bars (VBs) were fabricated, and their passive fit was assessed clinically. After sectioning and intraoral re-splinting, splinted verification bars (SVBs) were digitized using reverse scan bodies and a laboratory scanner to fabricate new verification bars (NVBs). Linear and angular deviations between datasets (IOS, VB, SVB, NVB) were analyzed using metrology software and statistically evaluated with Welch’s ANOVA and post hoc tests (α = 0.05). All VBs and NVBs demonstrated passive fit clinically. Mean linear deviations were 12 μm between IOS and VB, 50 μm between VB and SVB (p = 0.001), and 26 μm between SVB and NVB (p = 0.20). Mean angular deviations were 0.18° between IOS and VB, with six measurements > 0.4°; 0.79° between VB and SVB (p = 0.01), with seven measurements > 0.4°; and 0.06° between SVB and NVB, with four measurements > 0.4°. Within the limitations of this single-patient evaluation and the favorable two-implant mandibular configuration, intraoral scanning provided sufficient accuracy for fabricating passively fitting restorations on two implants in the edentulous mandible. Measurable linear and angular deviations did not compromise clinical fit in this case. The use of reverse scan bodies may be effective in cases of misfit after intraoral re-splinting, especially in more complex full-arch workflows, as only minor linear and angular deviations were observed in the NVBs with integrated abutments.

Read PDF

Similar papers

Open access Sep 2026

Model-free digital-correction workflow for multi-implant restorations: A clinical proof-of-concept study.

PURPOSE This clinical proof-of-concept study evaluates the feasibility and accuracy of a digital workflow for fabricating and correcting implant-supported restorations of multiple dental implants in an edentulous maxilla using intraoral scanning and reverse-scan bodies. METHODS An intraoral scan (IOS) was performed u...

A. Kernen-Gintaute, M. Akulauskas, F. Kernen et al. · 0 citations
Open access Sep 2026

Accuracy and clinical passive fit of reverse and standard scan body protocols for complete-arch implant-supported digital impressions: An in vitro study.

Within the limitations of this in vitro study, the RSB protocol demonstrated accuracy comparable to the SCB protocol, with more stable implant position transfer in four-implant configurations and a high clinical passive fit rate, supporting its use as a reliable alternative in complete-arch digital implant workflows.

Rabia Kilicaslan Dasdelen, İkbal Leblebicioğlu Kurtuluş, K. Kılıç · 0 citations
Aug 2026

In Vivo Assessment of Complete-Arch Implant Impressions Using a Clinical Seating Score: A Proof-of-Principle Case Report.

The CSS may potentially provide a simple and standardized chairside method for evaluating the passive seating of complete-arch implant frameworks and help clinicians identify clinically relevant misfits before delivery of the definitive prosthesis and support more predictable decision-making during framework verificati...

Francesco Mintrone, F. Ferri, Rostyslav Havryltsiv et al. · 0 citations
Review Sep 2026

Static Computer-assisted Implant Surgery (sCAIS) in Partial Edentulism: Tooth-supported Guides

While Static computer-assisted implant surgery facilitates prosthetically driven implant positioning and minimally invasive approaches, it requires clinical expertise, careful workflow execution, and appropriate patient selection to achieve predictable outcomes.

Florian Marxer, N. Naenni, R. Kraus · 0 citations
#software testing Open access Sep 2026

Accuracy of Direct Intraoral Versus Reverse Scanning for Abutment-Level Implant Impressions: an In Vitro Study

This study indicates that direct intraoral scanning provides superior accuracy compared with RSTs, particularly in the posterior regions, whereas putty-only impressions exhibited substantially greater relative deviations, particularly in the posterior regions.

Sumit Deshpande, Diksha Rajkumar Kasnale, Konark N. Patil et al. · 0 citations
Open access Sep 2026

Digitization of a Single Tissue-Level Implant Without Scan Body - A Feasibility Study.

OBJECTIVE This in vitro feasibility study evaluated the agreement between virtual implant positions obtained from intraoral scans of a tissue-level implant with and without a scan body for single-crown restorations. METHODS Three intraoral scanners (TRIOS 5 (TRI), Primescan (PRI), and DCS Scan (DCS)) were used to dig...

F. Burkhardt, Ahmad Amro Baradee, B. Spies et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.