Within the limitations of this single-patient evaluation and the favorable two-implant mandibular configuration, intraoral scanning provided sufficient accuracy for fabricating passively fitting restorations on two implants in the edentulous mandible.
Abstract
Completely edentulous mandibles present a challenge for accurate intraoral scanning, which can compromise the passive fit of implant-supported restorations. Reverse scan bodies may improve the accuracy of implant position transfer and support a fully digital workflow. However, clinical evidence for their use in the edentulous mandible remains limited. In this single-patient prospective clinical evaluation, one fully edentulous mandible restored with two interforaminal implants was scanned ten times using an intraoral scanner (IOS). Based on each scan, titanium verification bars (VBs) were fabricated, and their passive fit was assessed clinically. After sectioning and intraoral re-splinting, splinted verification bars (SVBs) were digitized using reverse scan bodies and a laboratory scanner to fabricate new verification bars (NVBs). Linear and angular deviations between datasets (IOS, VB, SVB, NVB) were analyzed using metrology software and statistically evaluated with Welch’s ANOVA and post hoc tests (α = 0.05). All VBs and NVBs demonstrated passive fit clinically. Mean linear deviations were 12 μm between IOS and VB, 50 μm between VB and SVB (p = 0.001), and 26 μm between SVB and NVB (p = 0.20). Mean angular deviations were 0.18° between IOS and VB, with six measurements > 0.4°; 0.79° between VB and SVB (p = 0.01), with seven measurements > 0.4°; and 0.06° between SVB and NVB, with four measurements > 0.4°. Within the limitations of this single-patient evaluation and the favorable two-implant mandibular configuration, intraoral scanning provided sufficient accuracy for fabricating passively fitting restorations on two implants in the edentulous mandible. Measurable linear and angular deviations did not compromise clinical fit in this case. The use of reverse scan bodies may be effective in cases of misfit after intraoral re-splinting, especially in more complex full-arch workflows, as only minor linear and angular deviations were observed in the NVBs with integrated abutments.
PURPOSE
This clinical proof-of-concept study evaluates the feasibility and accuracy of a digital workflow for fabricating and correcting implant-supported restorations of multiple dental implants in an edentulous maxilla using intraoral scanning and reverse-scan bodies.
METHODS
An intraoral scan (IOS) was performed u...
A. Kernen-Gintaute, M. Akulauskas, F. Kernen et al.· Journal of Prosthodontic Res...· 0 citations
Within the limitations of this in vitro study, the RSB protocol demonstrated accuracy comparable to the SCB protocol, with more stable implant position transfer in four-implant configurations and a high clinical passive fit rate, supporting its use as a reliable alternative in complete-arch digital implant workflows.
Rabia Kilicaslan Dasdelen, İkbal Leblebicioğlu Kurtuluş, K. Kılıç· Journal of Prosthodontics· 0 citations
The CSS may potentially provide a simple and standardized chairside method for evaluating the passive seating of complete-arch implant frameworks and help clinicians identify clinically relevant misfits before delivery of the definitive prosthesis and support more predictable decision-making during framework verificati...
Francesco Mintrone, F. Ferri, Rostyslav Havryltsiv et al.· Journal of Esthetic and Rest...· 0 citations
While Static computer-assisted implant surgery facilitates prosthetically driven implant positioning and minimally invasive approaches, it requires clinical expertise, careful workflow execution, and appropriate patient selection to achieve predictable outcomes.
Florian Marxer, N. Naenni, R. Kraus· Forum implantologicum· 0 citations
This study indicates that direct intraoral scanning provides superior accuracy compared with RSTs, particularly in the posterior regions, whereas putty-only impressions exhibited substantially greater relative deviations, particularly in the posterior regions.
Sumit Deshpande, Diksha Rajkumar Kasnale, Konark N. Patil et al.· European Journal of Dentistr...· 0 citations
OBJECTIVE
This in vitro feasibility study evaluated the agreement between virtual implant positions obtained from intraoral scans of a tissue-level implant with and without a scan body for single-crown restorations.
METHODS
Three intraoral scanners (TRIOS 5 (TRI), Primescan (PRI), and DCS Scan (DCS)) were used to dig...
F. Burkhardt, Ahmad Amro Baradee, B. Spies et al.· E -journal of dentistry· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.