Aug 2026· Clinical and Experimental Dental Research· Vol 12· 0 citations· 35 references
Medicine
TL;DR
Bone density evaluation by measuring the DTV may provide a clinically useful method for the intraoperative evaluation at low‐density implant sites and reflects the existing bone volume of low‐density tissue and is correlated with primary stability.
Abstract
ABSTRACT Objectives Intraoperative bone assessment is critical for achieving primary implant stability, particularly at low‐density bone sites. Drilling torque value (DTV) has been proposed as an indicator of bone density and may help guide drilling preparation protocols to improve primary stability. However, the relationship between DTV and primary stability, especially histological bone parameters in biological bone, remains unclear. This study aimed to clarify the influence of different drilling protocols for primary stability at low‐density bone detected by DTVs in biological cancellous bones. Materials and Methods Cancellous bone blocks obtained from bovine ribs were used. A specially designed torque measurement drill was used to assess bone density intraoperatively. Based on the DTVs, low‐density bone sites corresponding to Misch D4 and D5 were selected. The dental Implants were placed using either a normal or undersized drilling protocol. The DTVs, insertion torque values (ITVs), and implant stability quotient (ISQ) were recorded. Histological evaluation was performed to assess the bone area fraction (BAF) around the implant. Results The ITVs were lower than the clinically recommended range for primary stability in both groups; however, they were significantly higher in the undersized group than in the normal‐sized group. The DTVs positively correlated with the ITVs in both groups. A positive correlation between DTV and ISQ was observed only in the normal‐sized group, whereas ITV was positively correlated with ISQ in both groups. Histological analysis revealed no significant difference in BAF between the two groups. BAF positively correlated with DTV, ITV, and ISQ. Conclusions DTV reflects the existing bone volume of low‐density tissue and is correlated with primary stability. Intraoperative assessment of drilling torque would facilitate the selection of appropriate drilling protocols to achieve primary stability. Bone density evaluation by measuring the DTV may provide a clinically useful method for the intraoperative evaluation at low‐density implant sites.
The use of sequential osseodensification protocols yielded superior mechanical stability parameters, specifically in IT and RT, in synthetic (polyurethane) bone models, but improvements in ISQ were predominantly noted in the denser type III model.
Silvio Yoshiaki Okagawa, A. D. de Souza, P. D. de Carvalho et al.· International Journal of Den...· 0 citations
BACKGROUND
Preoperative prediction of primary implant stability may improve treatment planning in the esthetic maxilla. This prospective clinical study in female patients evaluated whether CBCT-based bone density, alveolar ridge width, and histomorphometric trabecular bone content are associated with primary implant st...
Soaad Tolba Badawy, A. S. Elmahdy, Amal T. Badawi· The International Journal of...· 0 citations
The surgical bone drilling process is unavoidable in orthopedic, traumatological and dental applications for screw, plate and implant placement procedures. The mechanical and thermal effects generated during this process have a direct impact on both surgical success and post-operative recovery. The high axial forces, t...
Pınar Kızılışık, L. Uğur, K. Aydın et al.· Biomedical engineering and p...· 0 citations
PURPOSE
Achieving predictable implant stability in low-density maxillary bone (D3-D4) remains clinically challenging because reduced bone density is associated with greater early loss of stability and an increased risk of implant failure. Photobiomodulation (PBM) has been proposed to enhance osseointegration; however,...
Omer Ali Hama, S. Aloosi· The International Journal of...· 0 citations
The enhanced insertion torque, higher implant stability quotient, greater pull-out resistance, and increased removal torque suggest that variable pitch implant designs may improve primary stability in compromised bone conditions.
Smitha Sharan, K. Viswaja, Santoshi Kumari V et al.· European Journal of Prosthod...· 0 citations
Background: Primary stability (PS) is a crucial determinant of long-term dental implant success, particularly in compromised or low-density bone sites. While macrogeometry is known to influence initial mechanical anchorage, the specific contribution of thread dimensions across varying bone densities remains incompletel...
M. Tumedei, Ugo Graziani, A. Cipollina et al.· Bioengineering· 0 citations