Jul 2026· Journal of Applied Clinical Medical Physics· Vol 27· 0 citations· 18 references
Medicine
TL;DR
The proposed methodology demonstrated high sensitivity for detecting dosimetric deviations, with potential to enhance radiotherapy safety and effectiveness and guide objective replanning strategies.
Abstract
Abstract Background Head and neck cancer (HNC) has a high incidence in Brazil. Although Image‐Guided Radiation Therapy (IGRT) improves treatment precision, anatomical changes during the treatment course may compromise dose distribution and require replanning. Purpose This study investigated the correlation between exit dose fluence and anatomical volumetric variations during HNC radiotherapy. Subsequently, a decision support methodology was proposed and validated to flag potential dosimetric deviations and guide objective replanning strategies. Methods A retrospective study was conducted with 11 patients, totaling 312 fractions treated on a Halcyon‐E linear accelerator. Volumetric variations were derived from cone‐beam computed tomography (CBCT) and exit dose fluence maps from each fraction were compared with the reference from the first treatment day using gamma analysis (γ_(1%/1 mm) to γ_(5%/5 mm); 10% threshold). Correlations between normalized volumetric variation (ΔV) and gamma indices were assessed using Kendall's tau coefficient (α = 0.05). A decision support methodology for replanning (γ_(1%/1 mm) < 80% and γ_(2%/2 mm) < 90%) was proposed and retrospectively validated in an independent cohort of 20 patients, comprising 618 treatment fractions. Results Strong negative correlations were observed between ΔV and gamma indices, with γ_(1%/1 mm) showing the highest sensitivity (τ = −0.83), followed by γ_(2%/2 mm) (τ = −0.75). Volumetric variations exceeding 5% were associated with significant dosimetric degradation. The validation correctly identified all replanned patients and detected potential indicators of dosimetric divergence not recognized in routine clinical practice. Conclusions The thresholds γ_(1%/1 mm) < 80% and γ_(2%/2 mm) < 90%, combined with ΔV > 5%, proved effective for guiding replanning decisions. The proposed methodology demonstrated high sensitivity for detecting dosimetric deviations, with potential to enhance radiotherapy safety and effectiveness.
Proton therapy has been increasingly utilized in head and neck cancer (HNC) patients due to its unique property of the Bragg Peak. However, proton dose delivery is highly sensitive to positional variations and anatomical changes occurring during the treatment course. These changes can lead to deviations between planned...
Abstract Background Dose‐guided adaptive fractionation (DGAF) was proposed as a simpler alternative of adaptive radiation therapy, using organ variation simulation for proof of concept. However, its dosimetric benefit using actual daily anatomy changes in prostate cancer patients remains unclear. Purpose The purpose of...
G. Gevorkyan, Li-Bing Zhu, R. Tegtmeier et al.· Journal of Applied Clinical...· 0 citations
Daily CBCT image-guided couch corrections maintain dosimetric accuracy during hypofractionated prostate radiotherapy and support safe implementation of tight PTV margins in resource-constrained public-sector healthcare settings.
Leanore Legoale-Sebopa, Sheynaz Bassa, H. V. Maselesele· South African Journal of Onc...· 0 citations
Background: When cervical cancer patients are treated with external beam radiation therapy, patient-specific anatomical changes, particularly bladder filling, alter the position and shape of the target volume throughout treatment. Online adaptive radiotherapy (oART) accounts for these interfractional changes by generat...
Jasmine Penney, K. Chytyk-Praznik· Biomedical engineering and p...· 0 citations
This study investigates factors that affect dose delivery in rectal cancer radiotherapy and evaluates the resulting differences between planned and delivered treatment doses using intensity-modulated techniques. Twenty patients were included with 140 cone beam computed tomography (CBCT) images. A correlation analysis w...
Geanina-Mirela Catona, L. G. Marcu· Radiation and Environmental...· 0 citations
Background/Objectives: Online adaptive radiotherapy (oART) re-optimizes treatment on the anatomy of the day, but automatically generated plans require dosimetric verification and dose–volume assessment. We performed an end-to-end validation of the Varian Ethos workflow for prostate cancer, including cross-adaptation be...
M. Janiszewska, M. Raczkowski· Life· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.