Skip to content
Review Open access

Clinical Implementation and Validation of Automated Slice-to-Volume Reconstruction for Fetal MRI Using a Vendor-Neutral MONAI-Based Imaging Informatics Pipeline.

Aug 2026 · Journal of imaging informatics in medicine · 0 citations · 6 references
Medicine

TL;DR

In this single-center, single-vendor cohort, the pipeline returned radiologist-acceptable reconstructions within a clinically practical timeframe and Automated fetal MRI SVR was operationally feasible using a DICOM-based, vendor-neutral deployment architecture integrated with routine PACS workflow.

Abstract

This study aims to evaluate the clinical performance and operational reliability of a fully automated, vendor-neutral imaging informatics pipeline for fetal MRI slice-to-volume reconstruction using open-source Medical Open Network for Artificial Intelligence (MONAI) Deploy Express, DICOM routing, and PACS return. In this retrospective implementation study, consecutive singleton fetal MRI examinations performed at a tertiary fetal care center between October and December 2025 were processed using a MONAI Deploy Express pipeline triggered by DICOM routing. The pipeline performed automated series selection and motion-corrected SVR reconstruction for fetal brain and body imaging using routine single-shot fast spin-echo inputs. Reconstructed volumes were returned to PACS for radiologist review. Three fellowship-trained fetal radiologists independently scored reconstruction quality using a 5-point Likert scale. Primary outcomes included examination-level reconstruction acceptability, inter-reader reliability, failure modes, and operational time to PACS availability after transition to the finalized production workflow. Among 67 triggered examinations, 2 represented technical workflow events and were excluded from clinical performance analysis, leaving 65 examinations for image-quality evaluation. Mean gestational age was 28.9 weeks (range, 19-36 weeks) and most fetuses had structural abnormalities. Brain SVR was rated pass-or-higher in 59/65 examinations (90.8%) and body SVR was rated pass-or-higher in 57/65 examinations (87.7%). Inter-reader reliability was excellent for brain (ICC, 0.93) and body (ICC, 0.92) reconstruction quality assessments. Reconstruction failures were primarily associated with suboptimal or insufficient input stacks, severe fetal motion, amniotic fluid extremes, complex anatomic distortions, and early gestational age. In 57 consecutively processed examinations after finalized production integration, median time to PACS availability was 10 min 28 s for brain SVR and 11 min 50 s for body SVR. Automated fetal MRI SVR was operationally feasible using a DICOM-based, vendor-neutral deployment architecture integrated with routine PACS workflow. In this single-center, single-vendor cohort, the pipeline returned radiologist-acceptable reconstructions within a clinically practical timeframe. Multi-vendor and comparative reader studies are needed to establish geometric accuracy, generalizability, and diagnostic benefit.

Read PDF

Similar papers

Preprint Aug 2026

SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI

The SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientat...

Arnaud Boutillon, Naomi Clarke, T. Woodgate et al. · 0 citations
Open access Sep 2026

Towards Faster Fetal 3D CINE Cardiac MRI Reconstruction Using Region-Optimized Virtual Coils (ROVir).

A computationally efficient image-reconstruction pipeline for 3D balanced steady state free precession CINE fetal cardiac MRI that reduces radial streaking artifacts, increases effective temporal resolution, and improves diagnostic image quality compared with previous work is developed and evaluated.

M. Piek, J. Töger, E. Heiberg et al. · 0 citations
Open access Aug 2026

A commissioning workflow for quantitative ¹⁷⁷Lu SPECT/CT across different Siemens scanner–reconstruction configurations

A practical commissioning workflow to optimize ¹⁷⁷Lu SPECT/CT imaging across different commercial scanner–reconstruction configurations is developed and a practical framework for local ¹⁷⁷Lu SPECT/CT optimization is provided.

L. Lampertico, G. Muti, C. Carbonini et al. · 0 citations
#edge computing Open access Aug 2026

Task‐based evaluation of axial and multiplanar reconstructions in computed tomography: A volumetric analysis of spatial resolution, noise, and detectability

MPR image quality is typically inferior to axial images and deteriorates further when derived from thicker axial slices, therefore, appropriate selection of the reconstruction kernel, pixel size and slice thickness are essential to maintain diagnostic image quality.

P. Monnin, A. Viry, F. Becce et al. · 0 citations
Open access Sep 2026

Automated fetal magnetic resonance imaging lung segmentation for rapid lung volume estimation across diverse pulmonary hypoplasia phenotypes.

BACKGROUND Fetal magnetic resonance imaging (MRI)-derived lung volume measurements are used for prenatal risk stratification in conditions associated with pulmonary hypoplasia, but manual segmentation is time-intensive. OBJECTIVE To evaluate whether automated fetal MRI lung segmentation enables rapid and reliable vol...

J. Choi, Shruti Hegde, Jonathan A. Dudley et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.