Skip to content
Open access

Optimized Balloon-Expandable Transcatheter Aortic Valve Implantation and Clinical Outcomes

Aug 2026 · JACC: Advances · Vol 5, pp. 103037 · 0 citations · 33 references
Medicine

TL;DR

Optimal THV implantation was associated with improved early procedural safety and long-term THV durability in balloon-expandable TAVR and systematic fluoroscopic assessment of optimized valve implantation may enhance patient outcomes.

Abstract

Background The expansion of transcatheter aortic valve replacement (TAVR) to younger patients with longer life expectancy requires procedural optimization to enhance long-term valve durability. Objectives To evaluate the relationship between fluoroscopic determinants of optimal transcatheter heart valve (THV) implantation—coaxiality, implantation depth, and expansion—and clinical and valve-related outcomes. Methods In this cohort study, consecutive patients undergoing transfemoral TAVR with balloon-expandable prostheses (Sapien S3, Sapien S3 Ultra) between February 2014 and June 2022 were included. THV coaxiality, implantation depth, and expansion were assessed in the 3-cusp view following deployment using standardized protocols. Suboptimal implantation was defined as ≥1 unfavorable determinants (coaxiality ≥4.8°, depth ≥6 mm, or underexpansion ≥20%). Outcomes included the modified early safety endpoint, moderate or severe hemodynamic valve deterioration, and stage 2 bioprosthetic valve failure. Results Among 1,032 patients (mean age 81 ± 6 years, 35.1% female), suboptimal THV implantation occurred in 443 (42.9%) patients and was driven by noncoaxial deployment (n = 240, 23.3%), excessive implantation depth (n = 261, 25.3%), and underexpansion (n = 54, 5.2%). Suboptimal implantation was associated with a higher likelihood of the modified early safety endpoint at 30 days (43.3% vs 19.9%; adjusted odds ratio: 3.05; 95% CI: 2.30-4.04) and stage 2 bioprosthetic valve failure at 5 years (subHR: 4.40; 95% CI: 1.25-13.59). Patients with ≥2 determinants demonstrated higher rates of hemodynamic valve deterioration at 5 years (subHR: 3.48; 95% CI: 1.24-9.80). Conclusions Optimal THV implantation was associated with improved early procedural safety and long-term THV durability in balloon-expandable TAVR. Systematic fluoroscopic assessment of optimized valve implantation may enhance patient outcomes.

Read PDF

Similar papers

Aug 2026

Newer-generation balloon-expandable vs. self-expanding transcatheter aortic valves: a propensity score matched analysis.

Among patients treated with newer-generation transcatheter valves, SEV demonstrated more favorable hemodynamic performance compared with BEV, however, short- and mid-term mortality rates remained similar between the two groups.

M. Baudo, S. Sicouri, Dimitrios E. Magouliotis et al. · 1 citation
Sep 2026

Long-term outcomes after balloon- or self-expandable transcatheter aortic valve replacement in small aortic annuli.

The need for further investigations using larger cohorts and contemporary devices to validate long-term comparative outcomes of BEV and SEV in patients with SAA is underscore the need for further investigations using larger cohorts and contemporary devices to validate long-term comparative outcomes.

Toshinobu Ryuzaki, Kentaro Hayashida, Kei Kamata et al. · 0 citations
Open access Aug 2026

New-Generation Transcatheter Valves for Extremely Small Aortic Annuli

Background Patients with extremely small aortic annuli are at increased risk of residual gradients and prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR). Comparative data on contemporary valve platforms in this subset remain limited. Objectives The authors aimed to compare early clin...

Shinichi Shirai, H. Hioki, M. Yamamoto et al. · 1 citation
Open access Feb 2026

Transcatheter aortic valve-in-valve implantation for failed surgical aortic bioprostheses using the Navitor platform: early outcomes in a consecutive single-center cohort

Introduction Transcatheter heart valve implantation into a failed surgical heart valve (THV-in-SHV) is an established reintervention strategy for degenerated aortic bioprostheses; however, early procedural outcomes, discharge hemodynamics, and standardized safety remain clinically relevant in routine practice. Material...

R. Sobczyński, J. Trębacz, Paweł Kleczyński et al. · 0 citations
Sep 2026

Impact of Aortic Annulus Size on Clinical and Hemodynamic Outcomes of Transcatheter Aortic Valve Implantation With the Navitor Valve.

BACKGROUND Patients with small aortic annuli undergoing transcatheter aortic valve implantation (TAVI) are at risk of higher residual transvalvular gradients. Evidence on the performance of new-generation intra-annular self-expanding valves in this anatomical setting remains limited. AIMS To evaluate the impact of an...

Matteo Casenghi, S. Corradetti, Pasquale Paolisso et al. · 0 citations
Aug 2026

Seven-Year Clinical and Durability Outcomes of Balloon-Expandable Transcatheter Aortic Valve Implantation in a Turkish Single-Center Cohort.

In this Turkish single-center cohort treated during the early TAVI era, long-term outcomes reflected the advanced age and comorbidity burden of the study population and should be interpreted in the context of substantial competing mortality.

A. H. Konuş, A. Akyüz, Ahmet Özderya et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.