ZIF-67-Derived Hollow Nanozyme with Dual Quenching Mechanisms Coupled with DNA Walker as an Aptasensing Platform for Sensitive Detection of Acetamiprid.
Aug 2026· Analytical Chemistry· Vol 98 32, pp.
23838-23847
· 1 citation· 47 references
Medicine
Abstract
Acetamiprid (ACE) is a widely used neonicotinoid insecticide with high insecticidal efficacy; however, its residues in food and environmental matrices have raised concerns regarding potential risks to human health. In this work, a DNA walker amplification strategy integrating the dual electrochemiluminescence (ECL) quenching pathways of ZIF-67-derived hollow CoFe Prussian blue analogue nanozyme (denoted ZIF-67@CoFe PBA NZ) was proposed for sensitive detection of ACE. Through efficient self-assembly of luminol, Eu3+, and guanosine 5'-monophosphate disodium salt (GMP), the obtained luminol-Eu3+-GMP coordination polymer (Lu-Eu3+-GMP CP) exhibited aggregation-induced electrochemiluminescence (AIECL) characteristics and a stronger and more stable ECL signal. ZIF-67@CoFe PBA NZ exerted a favorable ECL quenching effect and achieved a quenching efficiency of 68.16% through reactive oxygen species (ROS) depletion and ECL resonance energy transfer (ECL-RET). Leveraging the above advantages and DNA walker-mediated signal amplification, the proposed ECL aptasensing platform enabled ACE detection, showing a broad linear range from 1.0 pg/mL to 100 ng/mL and a low detection limit of 0.43 pg/mL. This ECL aptasensing strategy exhibited excellent practical applicability and held great application prospects for food safety analysis.
Developing highly sensitive and stable electrochemiluminescence (ECL) biosensing platforms requires overcoming inherent limitations, such as aggregation-caused quenching (ACQ) of luminophores and coreactant-induced electrode passivation. In this work, we developed an ECL biosensor capable of detecting microcystin-LR...
BACKGROUND
T-2 toxin threatens global food security and ecological stability due to its potent toxicity and environmental persistence. Thus, it is essential for addressing this threat. While electrochemiluminescence (ECL) offers sensitive mycotoxin detection, traditional systems suffer from low luminescent efficiency,...
Hui-Ling Jiang, Jing Shi, Chun-Yan He et al.· Analytica Chimica Acta· 0 citations
This work presents a novel strategy for the highly sensitive detection of Gal-3, leveraging the synergistic dual-quenching mechanism to achieve excellent analytical performance, thereby holding significant promise for clinical diagnostics and early disease monitoring applications.
Tingting Ye, Zhu Wang, Xin-Xin Chen et al.· Microchimica Acta· 0 citations
Sensitive and accurate monitoring of arginase activity is significant for clinical diagnosis. Herein, a dual-enhanced aggregation-induced electrochemiluminescence (ECL) biosensor was constructed based on triple-ligand-protected gold nanoclusters (AuNCs), sequentially coating 6-aza-2-thiothymine-capped AuNCs with L-argi...
Li-Li Tong, Xue-Ke Luo, Yan Zhang et al.· In Analysis· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.