CORRELATION BETWEEN POINT-OF-CARE AND LABORATORY-BASED AUTOMATED BLOOD GLUCOSE TESTING

2026 · Asian Journal of Medical Research and Health Sciences · Vol 04, pp. 2512-2518 · 0 citations

TL;DR

It is indicated that glucometers tend to overestimate glucose levels, consistent with previous studies, and laboratory autoanalyzers remain the gold standard for accurate glucose estimation.

Abstract

Background:Diabetes mellitus is a growing global health concern, with rising prevalence particularly in low-and middle-income countries. Accurate blood glucose estimation is essential for diagnosis, monitoring, and prevention of complications. While glucometers provide rapid, convenient results at the point ofcare, laboratory autoanalyzer are considered more reliable. This study aimed to compare the accuracy and correlation between these two methods.Methodology: A comparative study was conducted on 150 patients above 18 years, including both diabetic and non-diabetic individuals. Capillary blood glucose was measured using a glucometer via finger prick, while venous blood samples were analysed using a laboratory autoanalyzer. Statistical analysis done by paired t-test.Result:The mean blood glucose level obtained from the glucometer was approximately 8.49 mg/dL higher than that of the autoanalyzer. A strong positive correlation was observed (r = 0.959), indicating that both methods follow a similar trend. However, the paired t-test (t = 4.68, p < 0.001) showed a statistically significant difference.Discussion:The findings indicate that glucometers tend to overestimate glucose levels, consistent with previous studies. This discrepancy may arise due to operational errors such as expired strips, improper sample handling, or device calibration issues. Such inaccuracies can lead to inappropriate clinical decisions, especially in critical glycemic conditions.Conclusion:Although glucometers are useful for routine monitoring and point-of-care testing, they are not fully interchangeable with laboratory methods due to significant bias. Laboratory autoanalyzers remain the gold standard for accurate glucose estimation.

Read PDF

Similar papers

Open access Aug 2026

Validation of Precision and Accuracy of Point-of-Care Testing Glucose Analyzers with a Standard Laboratory Method (Glucose Oxidase Method)

POCT glucose meters should be used cautiously and primarily for monitoring trends rather than definitive diagnosis or therapeutic decisions, as they have limited reliability for critical clinical decision-making.

E. Nwobodo, N. T. Emmanuel · 0 citations
Open access Oct 2026

Continuous glucose monitoring for diabetes mellitus in the perioperative and intensive care setting: a prospective observational validation study✰.

BACKGROUND In-hospital diabetes mellitus management currently relies on intermittent glucose monitoring with point-of-care (POC) testing, rather than continuous glucose monitoring (CGM). Most studies on CGM have focused on its benefits and accuracy in the outpatient setting, in contrast to the hospital setting, where t...

C. Pedersen, Aslak Johansen, A. Philipsen et al. · 0 citations
Open access Sep 2026

The Relationship Between Blood Glucose and Increased Total Cholesterol in Outpatients at the Telaga Biru Community Health Center in Pontianak

Blood glucose and total cholesterol are two important indicators of body metabolism that are interrelated. High blood glucose levels over a long period of time can affect lipid profiles, including increasing total cholesterol levels. This study aims to determine the relationship between blood glucose levels and increas...

Anjela Zotti, Etik Nurhayati, Ratih Indrawati · 0 citations
2026

A Descriptive Study on the Pattern of Random Blood Sugar Levels Among Patients Attending a Selected Health Centre

Background: Random blood sugar (RBS) estimation is a simple and commonly used laboratory parameter for assessing the blood glucose level of an individual at a particular point in time. It is useful for screening and identifying individuals who may require further evaluation for abnormal glucose metabolism. The interpre...

Bhagyashree C. K., Reema Jenifer · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.