Skip to content
Open access

Processing strategies for improving cortical thickness correspondence between low-field and high-field MRI in young people

Jul 2026 · bioRxiv · 0 citations · 28 references
Medicine Biology

Abstract

Portable low-field MRI systems are a promising complement to conventional high-field systems, enabling broader access to MRI. However, correspondence in cortical thickness estimates between low- and high-field MRI in young people remains limited despite its importance for neurodevelopment and psychopathology. To evaluate how multiple low-field image processing approaches improve cortical thickness correspondence with high-field MRI in a large sample of young individuals, we collected ultra-low-field (64mT) and high-field (3T) MRI data from a community sample of young people. We applied deep learning–based image processing approaches (SynthSR v1.0, SynthSR v2.0, recon-all-clinical, and recon-any) to low-field data acquired across multiple sequences (T1- and T2-weighted) and orientations (axial, coronal, sagittal, and multi-orientation), with and without resampling and/or co-registration. We assessed global, lobar, and regional cortical thickness correspondence with 3T MRI measures using Pearson and intraclass correlations. We compared pipelines using Steiger’s Z-tests and Fisher’s Z-tests. A total of 150 individuals (mean age, 18.63±5.07; 80 female) were included. We observed the highest global correspondence with recon-all-clinical applied to coronal T1-weighted images (r=0.40, pFDR=2.6e-05). At the lobar and regional levels, multi-orientation T2-weighted images processed with recon-all-clinical showed the highest correspondence across the greatest number of regions (4/12 lobes; 13/68 regions). The highest correspondence and largest improvements were in frontal, cingulate, and temporal regions, including the right pars triangularis (r=0.52, pFDR=4.78e-11; Z=4.78, pFDR=4.25e-06), right caudal anterior cingulate (r=0.47, pFDR=3.83e-09; Z=5.46, pFDR=1.32e-07), and left parahippocampal (r=0.58, pFDR=2.98e-14; Z=5.17, pFDR=6.01e-07). We observed significantly improved cortical thickness correspondence in low-field MRI in young people. The recon-all-clinical pipeline yielded moderate correspondence, particularly in frontal, cingulate, and temporal regions. Our results highlight the potential of low-field MRI as an affordable and scalable approach for assessing cortical thickness in young people.

Read PDF

Similar papers

Deep Learning-Based Denoising Techniques for Low-Field Knee MRI

Self-supervised methods showed superior performance over supervised and classical methods for low-field knee MR images, and validation in a larger dataset of knee at 0.55T is needed to further support this conclusion.

José Ignacio Menéndez Olave · 0 citations
Open access Aug 2026

ALFIE: Anatomy-aware enhancement of Low FIEld 64mT T2-weighted neonatal brain MRI for structural analysis

An anatomy-aware deep learning framework for enhancement of neonatal 64mT T2-weighted MRI improves anatomical visibility while preserving native ultra-low-field contrast and enabling quantitative structural analysis support the feasibility of quantitative neonatal neuroimaging at ultra-low field.

P. Cawley, A. Uus, K. Colford et al. · 0 citations
Aug 2026

Deep learning-based image domain reconstruction of undersampled low-field brain MRI: A comparative benchmark study of U-Net architectures.

A comprehensive comparative evaluation of six U-Net variants, including U-Net, Attention U-Net, Residual U-Net, Recurrent-Residual (R2) U-Net, Residual-Attention U-Net (RAU-Net), and U-Net++, for image domain reconstruction of low-field MRI data from the M4RAW dataset is presented.

Akif Ahmed Nasif Purno, K. M. T. K. Siddiki, S. M. Chapal Hossain · 0 citations
Open access Oct 2026

Deep Learning-Based Enhancement of Low-Field MRI Using CNN-GAN for High-Quality Image Reconstruction

Magnetic Resonance Imaging (MRI) is one of the most common non-invasive imaging modalities with the capacity to visualize internal human anatomical structures such as soft tissues and organs with high resolution. High-field MRI (i.e., 1.5 T and above) provides better image quality, but its high cost and expensive infra...

K. S. Deepashri, H. Vinutha · 0 citations
Open access Sep 2026

Bridging field strengths: fine-tuned deep learning models for 7T MRI white matter lesion segmentation in multiple sclerosis

Fine-tuning is an effective and practical strategy for adapting deep learning WML segmentation algorithms to 7T MRI, even with limited annotated data, and may be included in MS research workflows to facilitate multi-center collaborations with 7T MRI.

A. De Rosa, Haz-Edine Assemlal, D. Fetco et al. · 0 citations
2026

Measurement-Consistent Low-Field MRI Enhancement via k-Space Noise Modeling

Low-field magnetic resonance imaging (MRI) has gained increasing attention as a cost-effective and portable alternative to high-field MRI, particularly in resource-limited conditions. However, its inherently low magnetic field strength leads to reduced signal intensity and a low signal-to-noise ratio (SNR), resulting i...

Yutao Hu, Qi Liu, Tao Zhou et al. · 1 citation

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.