Inter- and intra-observer reliability of cobb angle measurement between orthopaedic residents and spine specialists.

Aug 2026 · Acta orthopaedica Belgica · Vol 92 2 · 0 citations
Medicine

TL;DR

Residents demonstrated markedly poorer inter-observer reliability compared to specialists, highlighting the impact of clinical experience on accurate end-vertebra selection and angle measurement.

Abstract

Cobb angle measurement is essential for diagnosing and monitoring scoliosis; however, its accuracy varies with observer experience. In many healthcare systems, including Oman, initial measurements are commonly performed by residents and influence referral urgency, follow-up intervals, and bracing decisions, where even small inaccuracies may alter clinical pathways. This study evaluated the inter- and intra-observer reliability of Cobb angle measurement among orthopaedic residents and spine specialists. A prospective comparative reliability study was conducted including 18 OMSB orthopaedic residents (PGY2-5) and five spine specialists. Each participant measured Cobb angles on five standardised standing scoliosis radiographs on two occasions, four weeks apart. Inter- and intra-observer reliability were assessed using the intraclass correlation coefficient (ICC) with a two-way random-effects, single-measurement, absolute-agreement model [ICC(2,1)], and Bland-Altman plots were used to assess intra-observer reproducibility. Mean Cobb angles ranged from 45° to 56°. Inter-observer reliability was poor among residents (ICC = -0.219; 95% CI -1.41 to 0.485) and remained low among specialists (ICC = 0.120; 95% CI -2.28 to 0.898). Intra-observer variation averaged approximately 5°, with a Bland-Altman mean bias close to zero and limits of agreement of ±5%. Negative ICC values indicated that between-observer variability exceeded within- observer consistency. Residents demonstrated markedly poorer inter-observer reliability compared to specialists, highlighting the impact of clinical experience on accurate end-vertebra selection and angle measurement. Targeted training modules and structured exposure during residency may improve measurement consistency, referral accuracy, and overall scoliosis management pathways.

View source

Similar papers

Open access Sep 2026

Interobserver Agreement Between Orthopedic Surgeons and Radiologists in Cobb Angle Measurement on Plain Radiographs in Patients with Scoliosis

Interobserver agreement in Cobb angle measurements was found to be low and the need for standardized measurement protocols in clinical practice is emphasized, and digital tools and artificial intelligence–assisted methods may improve measurement reliability.

Habip Eser Akkaya, Mithat Temizer, Omer Kocak et al. · 0 citations
Open access Aug 2026

MRI-Derived Scapular Superomedial Angle and Acromial Morphology: A Retrospective Cross-Sectional Reliability and Morphometric Association Study

Background/Objectives: The magnetic resonance imaging (MRI)-derived scapular superomedial angle (SMA) may serve as a continuous descriptor of scapular geometry. We evaluated whether SMA is associated with acromial morphology, examined SMA and subacromial space (SAS) across acromial categories, and quantified measuremen...

Sami Kandefer, Volkan Gür, Mehmet Burak Gökgöz et al. · 0 citations
Review Sep 2026

Inter-rater reliability between radiologists and orthopaedic surgeons when assessing lumbar degenerative disc disease using the Pfirrmann grading system.

INTRODUCTION The Pfirrmann grading system is widely used for assessing degenerative disc disease (DDD) on T2-weighted MRI but is criticised for its subjectivity. This study evaluates inter-rater reliability between radiologists and orthopaedic surgeons using this system. METHODS A retrospective review of 60 lumbar sp...

Harry Marland, J. McDonnell, Sally Pan et al. · 0 citations
Review Open access Sep 2026

Reliability of the figure-of-eight method for measuring foot and ankle edema: Prospective emergency department assessment and literature review

Objective: This study aimed to evaluate the inter- and intra-rater reliability of the figure-of-eight (FoE) method for measuring foot and ankle edema when performed by emergency medicine and orthopedic residents in the emergency department (ED). Methods: This prospective observational study was conducted at the ED of...

Seyit Mehmet Altan, M. Yeşilaras, Necmiye Yalçın Ocak et al. · 0 citations
Open access Oct 2026

Neck vs Head Interspace Ratios in Hallux Valgus: A Reliability Analysis of First Metatarsal Radiographic Measurements.

BACKGROUND The relationship between the intermetatarsal space and first metatarsal width has been proposed as a radiographic parameter for surgical planning in hallux valgus. However, the reproducibility of the previously described Head Interspace Ratio (HIR) has not been formally evaluated, limiting confidence in its...

Miguel Viana Pereira Filho, G. Ferreira, Peter Lam et al. · 0 citations
Open access Oct 2026

FP1.8 Is the Anterior Wall Index a Reliable Surrogate of Anterior Hip Coverage? Correlation With Anterior center Edge Angle and Interobserver Reliability Study

Abstract ICLB01 - The Instability Masterclass: Correcting Bone, Biology, and Bad Outcomes, Session Room 6 (BMCC Level 3), October 8, 2026, 10:30 - 12:30 Introduction Accurate assessment of anterior femoral head coverage is essential in hip preservation surgery. The anterior center-edge angle (ACEA), measured on false-p...

Orthopaedic Surgeon Pedro Pablo Amenábar Md, Martin Hettich, Orthopaedic Surgeon Pedro Pablo Amenábar Md et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.