The HF-peak method is reliable when SNR is high and breathing is regular but requires additional quality criteria beyond SNR alone in older adult populations where non-respiratory HF oscillations may confound spectral peak detection.
Abstract
Respiratory frequency is a critical biomarker in sleep medicine and circadian biology. We investigated whether the high-frequency (HF) component of heart-rate variability (HRV)—which reflects respiratory sinus arrhythmia (RSA)—can serve as a non-invasive proxy for breathing rate estimation from ECG or PPG. We employed a two-stage validation design: (1) a physiologically calibrated simulation study (N = 30 per condition, five conditions, 180 s recordings) for controlled error characterization using the PhysioNet ECG-ID Database (Electrocardiogram Identification Database, DOI: 10.13026/C2XW26) as the processing pipeline reference; and (2) pilot real-data validation in N = 10 older adult participants (mean age 71.3 years) with simultaneous ECG and thermistor respiratory reference measured using the East Medic Biotope Mini (1000 Hz). Results: Under controlled resting conditions, simulation yielded MAE = 0.46 bpm (SNR = 4.8). An empirical error formula MAE = 2.017 × SNR^(−1.187) (R2 = 0.71) was derived. In the real-data validation, 4/10 participants achieved MAE ≤ 2.0 bpm; the remaining 6/10 showed errors of 6–17 bpm attributable to non-respiratory HF oscillations, harmonic confusion, and breathing rate variability. The HF-peak method is reliable when SNR is high and breathing is regular but requires additional quality criteria beyond SNR alone in older adult populations where non-respiratory HF oscillations may confound spectral peak detection.
INTRODUCTION
Heart Rate Variability (HRV) is the variation in Inter Beat Intervals (IBIs) of a heart signal and a measure of the cardiovascular system's flexibility to changes not expected from other factors. Traditional methods use electrocardiography (ECG) and polysomnography (PSG), which are invasive, costly, and un...
Yue Zhang, Yongbo Liang, Yan-Hua Guo· Archives of Physiology and B...· 0 citations
The widespread adoption of wearable devices has created new opportunities for continuous monitoring of physical activity, cardiovascular health, and sleep patterns. However, it remains an open question to what extent the physiological and kinematic data provided by commercial smartwatches can be considered accurate and...
János Dávid Balogh, Attila Adamkó· Proceedings of the 13th Inte...· 0 citations
The DTRC sequence significantly enhances HRV assessment accuracy, offering a reliable tool for early detection of autonomic dysfunction in high-risk populations and its simplified correction process and improved sensitivity hold promise for clinical diagnostics and wearable health monitoring applications.
Shanglin Yang, Hongbin Zhou, Xuwei Liao et al.· Frontiers in Cardiovascular...· 0 citations
Estimating standard short-term (ST, 5 min) heart rate variability (HRV) metrics (derived from electrocardiogram (ECG)) using ultra-short-term (UST, $< 5$ min) segments of photoplethysmogram (PPG) is desirable for real-time, cost-effective HRV monitoring in critical care settings. Traditional PPG-based HRV estimation re...
Wei-Nan Wang, K. Kilgore, L. Najafizadeh· IEEE journal of biomedical a...· 0 citations
Heart rate variability (HRV) is a non-invasive marker of autonomic cardiovascular regulation that reflects beat-to-beat fluctuations in cardiac cycle length. Reduced HRV has been associated with adverse cardiovascular outcomes across multiple disease states, yet its clinical use remains limited by substantial interpret...
B. Ghazzal, Ibrahim Hasan, Nebras Hasan et al.· Frontiers in Cardiovascular...· 0 citations