Aug 2026· International Conference on Digital Image Processing· Vol 14351, pp. 143512D - 143512D-9· 0 citations· 16 references
Engineering
TL;DR
Experimental results demonstrate that the proposed lesion-robust framework for longitudinal brain CT registration based on MRguided image translation consistently outperforms conventional intensity-based registration methods as well as existing image-translation–assisted strategies in both quantitative metrics and visual alignment quality.
Abstract
Longitudinal brain computed tomography (CT) is routinely used to monitor disease progression in patients with focal lesions and other neuropathologies. Accurate registration across time points is essential for reliable quantitative analysis. However, this task remains challenging due to the intrinsically low soft-tissue contrast of CT, particularly between gray and white matter, and the presence of space-occupying lesions, which induce substantial anatomical deformation and violate the intensity-consistency assumptions underlying conventional registration methods. To address these challenges, we propose a lesion-robust framework for longitudinal brain CT registration based on MRguided image translation. Specifically, an Image-to-Image Schrödinger Bridge (I2SB) network is employed to translate CT images into pseudo-MR images with enhanced anatomical contrast. We then perform joint deformable registration on both pseudo-MR and original CT images, where pseudo-MR provides structurally informative guidance while CT enforces modality-consistent data fidelity. This joint formulation enables more reliable correspondence estimation in the presence of lesion-induced deformation and intensity inconsistencies. The resulting deformation field is subsequently applied to the original CT images to achieve accurate longitudinal alignment. We evaluate the proposed method on an in-house longitudinal CT dataset of patients with intracerebral hemorrhage. Experimental results demonstrate that our approach consistently outperforms conventional intensity-based registration methods as well as existing image-translation–assisted strategies in both quantitative metrics and visual alignment quality. By jointly leveraging contrast-enhanced structural cues and modality-consistent constraints, the proposed framework provides a robust solution for longitudinal brain CT registration in the presence of large lesions.
Liver computed tomography perfusion (CTp) imaging enables quantitative assessment of vascular dynamics but is highly susceptible to motion‐induced artifacts arising from breath‐hold variability and involuntary patient motion. These effects cause different portions of the liver to fall within the imaging field of view a...
Zhan Xu, Yao Zhao, Xin-Ru Chen et al.· Medical Physics (Lancaster)· 0 citations
It is suggested that even state-of-the-art DIR methods do not yet provide sufficiently accurate and consistent registration for unmonitored use in brain metastasis reirradiation dose accumulation, because accurate registration is a prerequisite for deformable dose accumulation.
Hengjie Liu, Manju Sharma, Xinyi Fu et al.· 0 citations
Slice-to-volume registration between ultrasound (US) and preoperative computed tomography (CT) imaging would enhance many minimally invasive interventions, for example by locating soft tissue structures intra-operatively that are discernible in CT. While optical tracking enables initial rigid registration, contact from...
Agnieszka Lach, Magdalena Wysocki, Feng Li et al.· 0 citations
Its high multi-center adaptability and stability in small-lesion segmentation make it suitable for cross-institutional promotion, providing reliable anatomical references for prognosis assessment, doctor-patient communication, and rehabilitation monitoring.
Jia-Tong Wang, Hong-Xun Cui, Yong-Hui Liu et al.· 0 citations
Magnetic Resonance Imaging (MRI) is a key modality in cancer treatment, providing high soft tissue contrast for the visualization of tumors and internal anatomy. Radiotherapy, which is widely used in treatments, requires precise tumor segmentation to ensure targeting the true tumor and minimizing radiation exposure to...
Konstantinos Georgas, T. Vagenas, Ioannis A Vezakis et al.· Journal of imaging informati...· 0 citations
This work introduces a novel surface-based diffusion bridge framework DB-SUiT for MRI-to-PET translation that operates natively on the cortical manifold and demonstrates high-fidelity synthesis that substantially outperforms other baselines.
Yi-Tong Li, A. Samoylova, Fabian Bongratz et al.· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.