A lightweight low-rate wrist SPO2 estimation framework that integrates motion-aware beat selection and perfusion-guided calibration is proposed that achieves the best 25 Hz performance and reduces PPG sensor power consumption for energy-efficient wearable implementation.
Abstract
Continuous oxygen saturation (SPO2) monitoring from photoplethysmography (PPG) is important for wearable health sensing, but wrist-based SPO2 estimation remains challenging due to subtle wrist micro-perturbations and inter-subject differences in local perfusion status. These factors can destabilize the red-to-infrared ratio-of-ratios (R) and reduce the reliability of conventional fixed R-SPO2 mapping. This paper proposes a lightweight low-rate wrist SPO2 estimation framework that integrates motion-aware beat selection and perfusion-guided calibration. The proposed method extracts beat-level alternating-current/direct-current (AC/DC) components from dual-wavelength PPG signals, computes beat-level R values, and uses accelerometer-derived motion scores to weight beats within each sliding window. A subject-specific perfusion reference is further used to guide calibration across different perfusion conditions. Experiments on a private wearable dataset show that the proposed method achieves the best 25 Hz performance, with an MAE of 2.305$\pm$1.113% and an RMSE of 3.117$\pm$1.743%, while maintaining performance comparable to the 100 Hz sampling rate and reducing PPG sensor power consumption for energy-efficient wearable implementation. These results demonstrate the effectiveness of the proposed framework for low-rate wrist SPO2 estimation under micro-perturbations.
Wrist-worn photoplethysmography (PPG) enables unobtrusive heart rate monitoring, but motion-related errors tend to cluster under specific conditions and are often masked by aggregate accuracy metrics. This study characterized those failure patterns and assessed whether wrist-sensor features could identify unreliable es...
Angel Xu· Theoretical and Natural Scie...· 0 citations
A real-time SpO2 estimation algorithm based on chest reflectance PPG that supports the technical feasibility of chest reflectance PPG-based SpO2 estimation and its accuracy under controlled desaturation conditions is developed and clinically evaluated.
Woo-Yong Lee, Jaeyeon Shin, Mih-Ye Song et al.· Italian National Conference...· 0 citations
Wrist-worn electrocardiogram (ECG) enables unobtrusive and continuous cardiac monitoring in daily life, but reliable heart rate (HR) and heart rate variability (HRV) estimation remains challenging due to limited labeled data and electrode placement area, and severe motion artifacts. Self-supervised learning (SSL) provi...
Yan-Qiu Hu, Zhi-Yu Jia, Si-Ying Chen et al.· Proceedings of the 4th Inter...· 0 citations
Wearable photoplethysmography (PPG) can return a plausible heart rate (HR) after motion or poor optical coupling has made the measurement unreliable. We treat HR reporting as a reliability-control problem and introduce an interpretable signal quality index (SQI) layer that reports coverage and residual error. On PPG-Da...
The feasibility of consumer-grade smartwatches as accessible platforms for deploying robust BP estimation algorithms is highlighted, though clinical reliability will require larger, more diverse populations and additional sensing modalities.
Jathushan Kaetheeswaran, Bo-Yi Ma, Ali Abedi et al.· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.