Skip to content
Conference

Feature Selection and Performance Analysis for Heart Rate Estimation from Smartphone Photoplethysmography

Jul 2026 · 2026 International Conference on Intelligent and Sustainable AI Systems (ICOSAAS) · pp. 92-97 · 0 citations · 21 references

Abstract

Smartphone cameras enable continuous, equipment-free heart rate monitoring, yet the photoplethysmography (PPG) signals they capture are susceptible to movement, contact instability, and environmental variation that differ sharply from controlled validation settings. This study evaluated heart rate estimation from smartphone PPG signals using a feature-based approach, five classical regression models, and Recursive Feature Elimination (RFE) on the BUT PPG v2.0.0 dataset (3,888 recordings from 50 subjects, ECG reference). A total of 21 features were extracted from time, morphology, frequency, and signal quality domains, normalized using Yeo-Johnson, and evaluated under a subject-wise 5-fold cross-validation scheme. SVR with an RBF kernel achieved the best performance (MAE 9.20 bpm, RMSE 12.05 bpm). Feature selection reduced the feature count from 21 to 12 with negligible performance loss (MAE 9.19 bpm), and a Jaccard Stability Index of 0.7513 indicated that the selected subset generalizes consistently. Condition-stratified error analysis revealed that signal quality is the primary error driver, with MAE rising from 6.49 bpm on clean signals to 9.91 bpm on noisy ones, and that dynamic activities such as walking (13.69 bpm), laughing (12.74 bpm), and coughing (11.62 bpm) produce the highest errors. These findings indicate that upstream signal quality assessment is a necessary component of a reliable smartphone PPG heart rate estimation system.

View source

Similar papers

Open access Sep 2026

Real-Time SpO2 Estimation from Chest Reflectance Photoplethysmography: Algorithm Development and Clinical Validation Against Arterial SaO2

A real-time SpO2 estimation algorithm based on chest reflectance PPG that supports the technical feasibility of chest reflectance PPG-based SpO2 estimation and its accuracy under controlled desaturation conditions is developed and clinically evaluated.

Woo-Yong Lee, Jaeyeon Shin, Mih-Ye Song et al. · 0 citations
Open access 2026

Interpretable Reliability Control for Wearable PPG Heart Rate Estimation

Wearable photoplethysmography (PPG) can return a plausible heart rate (HR) after motion or poor optical coupling has made the measurement unreliable. We treat HR reporting as a reliability-control problem and introduce an interpretable signal quality index (SQI) layer that reports coverage and residual error. On PPG-Da...

Ye-Kun Liang, Shi-Wei Zhang, Zhou Yang · 0 citations
Sep 2026

Accuracy improvement for heart rate monitoring from bed-based ballistocardiography signals with motion artifacts.

BackgroundBallistocardiography (BCG)-based heart rate (HR) monitoring faces accuracy degradation due to motion artifacts, limiting its practical deployment.ObjectiveThis study aims to enhance HR estimation reliability under motion-contaminated conditions while ensuring real-time performance.MethodsA hybrid system integ...

Ze-Ya Wang, Zhu-Mu Fu, Hua Wang et al. · 0 citations
Sep 2026

Heart rate variability and sleep monitoring using single-channel PPG signal analysis: techniques and applications.

INTRODUCTION Heart Rate Variability (HRV) is the variation in Inter Beat Intervals (IBIs) of a heart signal and a measure of the cardiovascular system's flexibility to changes not expected from other factors. Traditional methods use electrocardiography (ECG) and polysomnography (PSG), which are invasive, costly, and un...

Yue Zhang, Yongbo Liang, Yan-Hua Guo · 0 citations
Open access Sep 2026

Beyond Average Accuracy: Motion-Related Failure Patterns in Wrist-Worn Photoplethysmographic Heart-Rate Monitoring

Wrist-worn photoplethysmography (PPG) enables unobtrusive heart rate monitoring, but motion-related errors tend to cluster under specific conditions and are often masked by aggregate accuracy metrics. This study characterized those failure patterns and assessed whether wrist-sensor features could identify unreliable es...

Angel Xu · 0 citations
Open access Aug 2026

The role of dataset integrity, calibration and signal quality in neural network-based blood pressure estimation

Cuffless blood pressure (BP) estimation via photoplethysmography (PPG) and machine learning has been widely studied, yet reported accuracy remains below clinically acceptable levels, limiting adoption in sport, ambient living, and telemedicine. This study systematically examines potential error sources underlying these...

C. Fritzsche, V. Senner · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.