A handheld, robotic steerable catheter system that has the potential to shorten the length of future endovascular surgeries, and give clinicians the tools to resolve challenging clinical cases is presented.
Abstract
Fenestrated/Branched endovascular aneurysm repair (FEVAR/BEVAR) require surgeons to navigate catheters and guidewires into various branches of the abdominal aorta, before deploying stent grafts to alleviate pressure on the aneurysm. Previous clinical studies suggests that surgeons continue to struggle with vessel access using standard commercial instruments, prolonging the procedural time and inducing further complications. In this work, we present two contributions to solving this problem: 1) A bespoke 2-segment steerable catheter, consisting of 4 degrees of freedom to enhance dexterity. 2) An expandable, modular tendon-driven actuation platform that can accommodate for the redundancies introduced in our system. To fabricate the catheter, we capitalized on thermal fiber drawing, a technique that creates high-aspect ratio devices at scale, and processed the catheter with laser micro-machining to soften its tip. We evaluated the system using simulations, where we investigated the catheter's bending stiffness, then its steerability with in-vitro experiments in vascular phantoms. This handheld, robotic steerable catheter system has the potential to shorten the length of future endovascular surgeries, and give clinicians the tools to resolve challenging clinical cases.
Mechanical thrombectomy is a life-saving procedure used to treat ischemic stroke. It requires endovascular navigation through tortuous pathways. This navigation presents a particular challenge for some anatomy, such as type III aortic arches. This letter presents a steerable soft catheter tip that can augment existing...
Lauren Kadlec, J. Lawson, Garrison L. H. Johnston et al.· IEEE Robotics and Automation...· 0 citations
Endovascular interventions for complex aortic aneurysms—including juxtarenal abdominal aortic (JAAA), pararenal abdominal aortic (PRAAA), and thoracoabdominal aortic (TAAA) aneurysms—face inherent limitations, such as manufacturing delays and anatomical restrictions. In Japan, where commercial off-the-shelf branched or...
Background: Endovascular exclusion of popliteal artery aneurysms (PAAs) with long covered stent-grafts is valuable for patients unfit for open surgery but is undermined by late stent thrombosis, even in fully scaffolded segments without kinking, a failure best clarified by computational fluid dynamics (CFD), which requ...
Christos Chronis, K. Tzirakis, N. Kontopodis et al.· Methods and Protocols· 0 citations
Introduction Simulation-based training in endovascular procedures remains limited by the availability of biological vascular models that provide tactile feedback. Existing animal, cadaveric, synthetic, and virtual simulators incompletely reproduce the mechanical behavior of complex neurovascular anatomy. Methods Human...
Z. Itsekzon-Hayosh, E. Chung, B. Warren et al.· Frontiers in Neurology· 0 citations
Using a high-pressure balloon to do bioprosthetic valve remodeling (BVR) for a failed surgical non-fracturable aortic valve is thought to improve the expansion of a transcatheter heart valve (THV) during valve-in-valve transcatheter aortic valve replacement (ViV-TAVR). However, the risks and benefits of this approach r...
Y. Tsai, Ching-Wei Lee, Su-Chan Chen et al.· Catheterization and cardiova...· 0 citations