Skip to content
Open access

Rotating SIM Technique—A Novel Technique for Retrieval of Retained Guidewire from Internal Iliac Vein

Jul 2026 · Journal of Clinical Interventional Radiology ISVIR · 0 citations · 5 references

TL;DR

This case describes a practical use of a reverse curved catheter (SIM1) to engage and displace intravascular retained foreign body lodged deep in the internal iliac vein and proposes that this technique is an easy and effective technique to reposition foreign bodies from anatomically difficult regions to more favorable locations from where snaring can be easily performed.

Abstract

Abstract As the number of endovascular procedures is increasing, the incidence of intravascular foreign body (IFB) is also on a rising trend. Broken catheter fragments or leftover guidewires are common IFB. These foreign bodies can embolize, causing injury to vital structures or may cause vascular thrombosis. Standard snare retrieval techniques may fail when the accessible end of the foreign body lies deep within a small or acutely angled branch vessel. We describe a branch vein-specific Simmons (SIM)-based rotational repositioning variant that enables the retrieval of a retained guidewire impacted in the internal iliac vein. A 39-year-old male patient with chronic kidney disease presented with a retained guidewire in the venous system after placement of a dialysis catheter in the right internal jugular vein. The J-tip of the guidewire was lodged deep into the right internal iliac vein, and retrieval of the guidewire by grasping its tip and snaring using a standard loop snare was not feasible. The proximal end was also not thought to be safely retrievable by simply pulling out the catheter because it could not be easily accessed for manual extraction. Taking out the catheter could have caused the guidewire to further migrate and loss of the only functioning dialysis access. So, a reverse curved catheter (SIM1) was used to engage the guidewire in its primary curve. After engagement, the catheter-guidewire combination was pushed up, placing the guidewire in the right common iliac vein, from where it was snared out. Our case describes a practical use of a reverse curved catheter (SIM1) to engage and displace intravascular retained foreign body lodged deep in the internal iliac vein. We propose that this technique is an easy and effective technique to reposition foreign bodies from anatomically difficult regions to more favorable locations from where snaring can be easily performed.

Read PDF

Similar papers

Open access Sep 2026

Comparison of Guidewire Passage in the Presence of Subclavian Vein Valves During Ultrasound-Guided Catheterization: A Two-Case Series

Ultrasound-guided subclavian vein catheterization significantly improves procedural success and safety; however, intra-luminal dynamic structures such as venous valves can interfere with guidewire advancement. This case series compares two distinct clinical scenarios involving pre-procedurally identified subclavian vei...

Ju Hyeon Lee, Dahye Moon, H. Heo et al. · 0 citations
Open access Sep 2026

An effective and novel technique for antegrade ureteral stent placement: The “hydroguiding” method

Ureteral obstructions are clinically significant conditions that may develop due to benign or malignant causes and threaten renal function. Although the retrograde stenting method is generally preferred as the first-line approach, its success rate markedly decreases in cases with malignant or severe strictures. Whi...

Rıdvan Akbulut, Aygün Katmerlikaya, Mahmut Demirci et al. · 0 citations
Case report Open access Sep 2026

Successful endovascular treatment for retroflexed anterior tibial artery origin in chronic limb-threatening ischemia

The success rate of endovascular treatment (EVT) for infrapopliteal lesions has increased significantly; however, EVT can be particularly challenging when the anterior tibial artery (ATA) originates in a retroflexed configuration. An 86-year-old man presented with rest pain in the right lower extremity (Rutherford cate...

Tetsuya Nomura, Shogo Kaketaka, Tokuaki Bando et al. · 0 citations
Case report Open access Sep 2026

Endovascular Retrieval of Unraveled Coils Extending Along the Aorta Due to Guidewire Fracture During Percutaneous Coronary Intervention: The Snare and Trap Technique.

Guidewire entrapment and fracture is an uncommon but potentially hazardous event during percutaneous coronary intervention (PCI), and may lead to thrombosis, vessel occlusion, and embolization. In clinical practice interventional cardiologists are aware that such complication is not that rare, especially in complex PCI...

Pietro Mazzarotto, Delio Tedeschi, Simone Morganti et al. · 0 citations
Case report Open access Sep 2026

Gutter Rotation Technique for Percutaneous Ipsilateral Retrieval of a Ruptured SAPIEN-3 Balloon.

Balloon rupture during transcatheter aortic valve replacement (TAVR) with balloon-expandable valves is a rare but potentially serious complication that may result in incomplete valve expansion, difficult device retrieval, and vascular injury. We report the case of an 88-year-old woman with severe calcific aortic stenos...

Anne Venkata Ganeshkumar, Guru Chaithanya Kumar Chagalakondu, Naveen Kumar Murki et al. · 0 citations
Review Oct 2026

Wireless Tenzing Crossing of Large Vessel-Occlusions - Feasibility of a Technique After Failed Stroke Thrombectomy with Traditional Approaches.

A proof-of-concept case-series is a feasibility report that wireless Tenzingplasty may offer a rescue strategy for resistant LVO, particularly in cases involving ICAD or failed wire access.

F. Behzadi, K. Zurcher, Isabel L. Bauer et al. · 0 citations