Skip to content
Open access

Design and Construction of Remote Control Gate Cross Bar

Aug 2026 · Physical Science International Journal · Vol 30, pp. 1-14 · 0 citations

TL;DR

The developed prototype demonstrated the practical integration of locally available mechanical and electronic components for wireless gate operation, although further evaluation under broader field conditions is required.

Abstract

Manual operation of barriers at access points can increase operator workload and may delay vehicular movement. This study designed, constructed, and evaluated a remote-controlled gate cross bar intended to provide a low-cost wireless alternative for automated access control. The system integrated an Arduino Uno microcontroller based on the ATmega328P, a 433 MHz radio-frequency transmitter and receiver, a 12 V DC geared motor, a motor-driver module, limit switches, relay control, status indicators, and a mechanical               barrier arm. The control program processed remote commands, activated bidirectional motor movement, and used limit-switch feedback to stop the barrier at the fully open and closed positions. Performance was evaluated under outdoor conditions using 20 opening-and-closing cycles. The measured parameters included response time, opening time, closing time, remote operating range, and operational consistency. The system recorded a mean response time of 0.61 ± 0.05 s, a mean opening time of 2.43 ± 0.08 s, and a mean closing time of 2.48 ± 0.07 s. Stable RF communication was maintained over an average distance of 25 ± 1.2 m. Temporary electromagnetic interference, metallic obstacles, reinforced-concrete walls, and minor power-supply fluctuations affected signal reception or motor speed during some observations. No mechanical  failure, motor overheating, excessive vibration, or structural deformation was reported during testing. The developed prototype demonstrated the practical integration of locally available mechanical and electronic components for wireless gate operation, although further evaluation under broader field conditions is required.

Read PDF

Similar papers

Conference Sep 2026

Apparatus and Control of Remotely Operated On-Demand Barrier to Mitigate Well Intervention Risks

Maintaining well barrier integrity is crucial to prevent uncontrolled flow during drilling, completion, well intervention, and plug-and-abandonment (P&A) operations, thereby safeguarding personnel, assets, the environment, and company reputation (Vrålstad, et al., 2012). V0-qualified plugs have long served as trusted...

A. Khalil, M. A. Effendi, S. Ross · 0 citations
Review Open access Aug 2026

PLC-Controlled Rack and Pinion-Based Automated Railway Barricade System: Design, Structural Validation, and Prototype Implementation for Enhanced Level Crossing Safety

Railway level crossings remain a persistent source of accidents and fatalities on mixed road-rail networks, particularly where crossings are unmanned or rely on manual gate operation. This paper presents the design, structural validation, and prototype implementation of an automated railway barricade in which a Program...

Akhil Deshpande, Vinayak V. Kulkarni, Vaidehi P. Deshpande et al. · 0 citations
Sep 2026

A method for detecting the status of high-speed rail relays based on STM32

In response to the problems of insufficient measurement accuracy and poor reliability in the traditional manual detection method for the contact pressure of high-speed railway relays, this paper proposes a relay contact pressure state detection system based on STM32. The system uses a thin-film pressure sensor to adher...

Zhuo-Hang Li, Xiao-Lin Wang, Zhi-Xin Wen · 0 citations
Open access Aug 2026

Real-time Monitoring and Remote Control of Laboratory Furnaces using MQTT and Role-Based Access Control

The modernization of laboratory infrastructure requires secure, reliable remote monitoring systems to replace inefficient manual supervision. This study presents the design and implementation of a Web-based Supervisory Control and Data Acquisition (SCADA) system for laboratory furnaces, incorporating Proportional-Integ...

Adilia Getia Haqia Ilmi, Linda Ratna Kholifah, Syada Saleha et al. · 0 citations
Open access Oct 2026

Improvement Of Proximity Sensor-Based Interlock System On Butterfly Valve And Danfoss Vlt Vfd Inverter To Prevent Screw Pump From Operating With The Valve Closed

General Background Industrial piping networks utilize three-phase induction drives and isolation devices to ensure continuous and controlled fluid transfer. Specific Background Running a fluid transfer system against a closed discharge path generates trapped kinetic energy, rapidly increasing internal casing temperatur...

Septian Putra Arifin, S. Syahrorini · 0 citations
Conference Sep 2026

Express Lateral Identification and Entry Using an Autonomous Electrical Intervention Tool

Accessing extended reach multilaterals for logging or stimulation operations can be challenging from the standpoint of equipment capability, resource and time utilization. Field experience has shown that hydraulic access methods require a lot of time and large volumes of fluid from surface, leading to higher operatio...

E. Al Munif, A. Saeed, C. Ejim et al. · 0 citations