AID initiation after a short period of pump therapy in T1D patients significantly improved glycemic control over 6 months, with no safety concerns but no measurable improvement in quality of life.
Abstract
Introduction Automated insulin delivery (AID) has been shown to be effective in routine care in type 1 diabetes (T1D). However, its effectiveness without prior insulin pump therapy lasting more than 6 months remains poorly investigated. Material and methods This prospective, multicenter study assessed the 6-month AID effectiveness in patients with T1D for more than one year, not previously treated with an insulin pump, with HbA1c level <10% and aged over 8 years (y). The primary study endpoint was the change in time in range (TIR, 70-180 mg/dl) from AID initiation to 6 months. Results A total of 43 patients with T1D (38 adults, 5 aged under 18y) were enrolled in 9 centers. Mean age was 37±16y, 56% were male, T1D duration was 14±12 years and baseline HbA1c level was 7.6±0.8%. Patients initiated AID (Medtronic® MiniMedTM 780G), after 2.9±1.0 months of non-automated pump therapy. After 6 months of AID (n=39), TIR increased by 17.6±11.2% (p<0.0001), % time >180 mg/dl decreased by 15.3±12.1% (p<0.0001), % time >250 mg/dl by 5.9±11.2% (p=0.0001), % time <70mg/dl by 1.5±3.4% (p<0.002), % time <54mg/dl by 0.6±2.3% (p=0.05). Mean HbA1c level decreased by 0.6±0.6% (p<0.0001) and mean sensor glucose by 20.3±37.5mg/dl (p= 0.0004). The INSPIRE questionnaire score was unchanged. Adverse events included 2 non-severe ketosis episodes and 2 local skin reactions. Conclusion AID initiation after a short period of pump therapy in T1D patients significantly improved glycemic control over 6 months, with no safety concerns but no measurable improvement in quality of life.
CGM is safe in very young children, with AID systems proving superior to traditional therapy, and real-world evidence supports incorporating AID consideration into future international guidelines from the time of pediatric diagnosis.
M. Marigliano, A. Scaramuzza, C. Arnaldi et al.· Diabetes Technology & Therap...· 0 citations
AIMS
This study aims to evaluate the effectiveness and safety of early AID initiation combined with a telehealth support programme in individuals recently diagnosed with type 1 diabetes (T1D) in mainland China.
MATERIALS AND METHODS
This prospective, single-arm, observational study sequentially enrolled individuals w...
Yong-Wen Zhou, Ying Ni, Hong-Rong Deng et al.· Diabetes, obesity and metabo...· 0 citations
Introduction: Children and adolescents with type 1 diabetes (T1DM) are managed with multiple daily injections of insulin (MDI) or with an insulin pump. Understanding the advantages and disadvantages of each treatment modality is important for personalizing the diabetes care plan and meeting patients' various needs.
Ai...
Fatema Khalil Al Qanea, Y. Alanazi, Haifa Alfaraidi et al.· International Journal of Chi...· 0 citations
INTRODUCTION
The MiniMed™ 780G (MM780G) advanced hybrid closed-loop system has been shown to help improve glycemic control compared with continuous glucose monitoring plus multiple daily injections of insulin (MDI) in people with type 1 diabetes (T1D). The long-term health economic outcomes with MM780G versus MDI + CGM...
S. Glastras, Meaghan Read, Asli Zeynep Ozdemir Saltik et al.· Advances in Therapy· 0 citations
Background: The global rise of type 2 diabetes (T2D) presents significant healthcare challenges in diagnosis, prevention, and treatment. This study compares basal insulin and modified-release gliclazide to assess their effectiveness in managing glycemic control and other clinical factors in T2D patients. Methods: This...