Combining Clinical LAFOV PET/CT with a Digital Twin Providing Motion-Free Ground Truth Reveals Quantitative Trade-offs in Respiratory Motion Correction
Clinical PET imaging with a realistic digital twin and corresponding motion-free ground truth enabled objective validation of respiratory MoCo beyond conventional clinical evaluation, highlighting the value of ground-truth-based validation for developing and benchmarking respiratory motion correction and quantitative PET on LAFOV PET/CT systems.
Abstract
Purpose: Respiratory motion remains a major source of quantitative bias in PET and becomes increasingly relevant for high-sensitivity long axial field-of-view (LAFOV) PET/CT. Although numerous respiratory motion correction (MoCo) methods have been proposed, their quantitative accuracy cannot be established clinically because a patient-specific motion-free reference is fundamentally unavailable in vivo. This study combined clinical PET imaging with a digital twin, a realistic representation of both the PET/CT system and the patient, to objectively validate respiratory MoCo against a corresponding motion-free reference. Methods: Twenty patients (10 [18F]FDG with predominantly pulmonary lesions and 10 [18F]SiFAlin-TATE with predominantly hepatic lesions; total 135 lesions) were analyzed. The digital twin combined a validated LAFOV PET/CT simulation model with an anatomically realistic phantom containing 14 lung and liver lesions, two patient-derived respiratory patterns, and respiratory motion amplitudes of 2 and 3 cm, generating patient-like datasets with corresponding motion-free references. Data-driven and image-based MoCo were evaluated using lesion morphology, SUVmean, SUVmax, and metabolic tumor volume (MTV). Results: In patients, data-driven MoCo produced larger SUVmean increases than image-based MoCo for liver (48.1{+/-}18.9% vs. 17.0 {+/-} 12.0%; p<0.01), lower-lung (32.5{+/-}21.2% vs. 16.3{+/-}15.6%, p=0.06), and upper-lung lesions (28.4{+/-}32.0% vs. 10.4 {+/-} 17.2%; p<0.01), with similar findings for SUVmax and larger MTV reductions. Simulation revealed marked motion-induced SUVmean underestimation before correction, particularly in liver (-31.2{+/-}6.8%) and lower lung (-15.5{+/-}13.9%). Relative to the motion-free reference, data-driven MoCo most accurately recovered hepatic uptake (4.3{+/-}11.7% vs. -10.0 {+/-} 9.2%; p=0.01) but overestimated pulmonary uptake (lower lung: 19.8{+/-}16.3% vs. -1.6 {+/-} 10.2%; p=0.02). SUVmax showed the same regional behavior, whereas image-based MoCo yielded MTV estimates closer to the reference. Quantitative recovery was largely independent of respiratory pattern, while larger motion amplitudes mainly affected image-based MoCo. Conclusion: Combining clinical PET with a realistic digital twin and corresponding motion-free ground truth enabled objective validation of respiratory MoCo beyond conventional clinical evaluation. Larger correction-induced quantitative changes should not be equated with greater quantitative accuracy. Instead, MoCo performance was region- and metric-dependent, highlighting the value of ground-truth-based validation for developing and benchmarking respiratory motion correction and quantitative PET on LAFOV PET/CT systems.
In PET/CT imaging, CT frequently accounts for more than 50% of the total radiation exposure, even when used solely for attenuation correction and anatomical localisation. This poses a major limitation for dose-sensitive populations, including pregnant women and paediatric patients. This study systematically evalu...
Georgios I. Angelis, Y. Gholami, K. Willowson et al.· EJNMMI Physics· 0 citations
TLCE-morph, a Tri-Path Lie Convolution Encoder-based learning framework for deformable respiratory motion correction in thoracic PET, achieves the most favorable overall quantitative performance and shows more consistent local structural recovery in representative motion-sensitive regions.
Hui Zhou, Long-Xi He, Si-Yu Wang et al.· Frontiers of Physics· 0 citations
Objectives FDG-PET is an important imaging tool in evaluation of neurological disorders, including drug-resistant epilepsy. Head motion can degrade PET image quality; however, the extent in routine examinations remains insufficiently characterized. This retrospective study aimed to quantify the magnitude and pattern of...
K. Mackova, K. Dudasova, P. Ježdík et al.· medRxiv· 0 citations
The primary quantitative endpoint, the Ki value, remains highly robust across all evaluated framing protocols, software platforms, and reconstruction algorithms and facilitates cross-center data harmonization and clinical standardization for multi-center dynamic 18F-FDG PET/CT.
Ya-Rong Zhang, X. Wumener, Mao-Qun Zhang et al.· Frontiers in Oncology· 0 citations
PURPOSE
The increased sensitivity of long-axial field-of-view (FOV) digital PET/CT systems enables potential reductions in administered activity and/or acquisition time with respect to standard-field-of-view systems and established clinical protocols, while preserving quantitative performance. This study aimed to evalu...
A. Piai, B. Bordigoni, L. Antunovic et al.· Physica medica (Testo stampa...· 0 citations
This study investigated the relationship between body size, administered activity, and image quality (IQ) using two patient-like phantoms representing normal and obese body profiles, and demonstrated the count rate capabilities up to and beyond the saturation limit.
Nanna Overbeck, Zuzanna Czeluśniak, Søren Holm et al.· Physics in Medicine and Biol...· 0 citations